Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2018-09-27-17
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 09/27/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/01/2018
The quantity of what the sample constitutes: 35
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Comments: Unknown
Reel/Coil/Pack Number(s):
Number of Coils: Unknown
Group Number: 10895
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0596818-2, S0575418, S0596518-2, S0596018-3
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire
DIME Test ID: 2018-09-27-17-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/03/2018
Date Tested: 10/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0596818-2 | S378252-1 | 0.215 | 60647 | 55868 | 28.7 | 1.92 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
72 F
|
Extensometers
|
E88768
|
DIME Test ID: 2018-09-27-17-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/03/2018
Date Tested: 10/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0596818-2 | S378252-3 | 0.215 | 60419 | 55670 | 28.6 | 1.7 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
72 F
|
Extensometers
|
E88768
|
DIME Test ID: 2018-09-27-17-3
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/03/2018
Date Tested: 10/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0575418 | S334673-1 | 0.213 | 60253 | 55193 | 28.9 | 2.01 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
72 F
|
Extensometers
|
E88768
|
DIME Test ID: 2018-09-27-17-4
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/03/2018
Date Tested: 10/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0575418 | S334674-1 | 0.213 | 60297 | 55124 | 28.7 | 2.12 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
72 F
|
Extensometers
|
E88768
|
DIME Test ID: 2018-09-27-17-5
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/03/2018
Date Tested: 10/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0596518-2 | S334679-4 | 0.213 | 59698 | 54272 | 28.5 | 1.9 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
72 F
|
Extensometers
|
E88768
|
DIME Test ID: 2018-09-27-17-6
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/03/2018
Date Tested: 10/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0596018-3 | S334683-4 | 0.213 | 60165 | 55323 | 28.8 | 2.04 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
72 F
|
Extensometers
|
E88768
|
DIME Test ID: 2018-09-27-17-7
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/03/2018
Date Tested: 10/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0596018-3 | S378261-3 | 0.213 | 60150 | 55732 | 28.6 | 1.68 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
72 F
|
Extensometers
|
E88768
|