Print Report | Back to Sample Detail

Sample Record for 2018-09-27-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-09-27-4
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 09/27/2018
Date that the sample was received by the laboratory/organization performing the testing: 09/27/2018
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Metakaolin
From where was the sample collected: Source
Laboratory sample identification: CM185865
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: ACT

Material Information

Brand: ACT
Mill: Powerpozz
Type of Cementitious Material: Class F or N Flyash

Test Results

Test 1 of 2

DIME Test ID: 2018-09-27-4-2
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 03/26/2019
Date Tested: 03/26/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: Water demand for this material exceeds allowable limits of ASTM C618. Testing was halted and the material removed from the AML.
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? no
Compressive strength of 1st specimen (psi) 0 psi
Compressive strength of 2nd specimen (psi) 0 psi
Compressive strength of 3rd specimen (psi) 0 psi
Average Compressive strength (to nearest 10 psi) 0 psi

Test 2 of 2

DIME Test ID: 2018-09-27-4-4
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 03/26/2019
Date Tested: 10/04/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Correction Factor (CF) 0.21 %
Corrected Residue (Rc) 11.49 %