Print Report | Back to Sample Detail

Sample Record for 2018-07-31-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209695 DEA: 08347704 EFIS: 0800000616 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-SR-58-0/12.9
Work Description: (Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location Description: SR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Contractor Name: KIEWIT INFRASTRUCTURE WEST CO.
Contractor Address: 2215 E 1ST STREET, VANCOUVER, WA 98661
Resident Engineer: Shaine Shahidi Structure Rep.: Osama Abdalla

Sample Information

DIME Sample ID: 2018-07-31-15
TL Number from the TL Form: 20180731B
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/31/2018
Date that the sample was received by the laboratory/organization performing the testing: 08/02/2018
The quantity of what the sample constitutes: 4
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Manufacturer
Laboratory sample identification: 976-0731B
Structure unique identifier: at 1046
Structure name: at 1046
The fabricator/manufacturer/facility name: KIEWITT

Material Information

The concrete mix design number: LB18-0031
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: 66
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: keiwit plant
A detailed description of where the material sample was collected: plant
Where the material sample would have been placed if not sampled: at 1046
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2018-07-31-15-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/03/2018
Date Tested: 08/03/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: DESIGN STRENGTH 530PSI IN 7 DAYS MEET
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 600 psi
Maximum load on cylinder 1 16730 lb
Maximum load on cylinder 2 17100 lb
Compressive strength of cylinder 1 591.8 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 604.9 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 3 days
Age of specimen in hours no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2018-07-31-15-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens08/03/201808/07/2018Minh PhamCT D08 - Fontana Southern Regional Laboratory