Print Report | Back to Sample Detail

Sample Record for 2018-06-20-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Shimmick/FCC/Impregilo (SFI) JV
Contractor Address: 11 Golden Shore, Suite 330, Long Beach, CA 90802
Resident Engineer: Structure Rep.: Sami Deeb

Sample Information

DIME Sample ID: 2018-06-20-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Independent Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/20/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/03/2018
The quantity of what the sample constitutes: 1 lot
A brief description of the sample: A325 Bolt, nut and washer
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: LeJeune Bolt Company

Material Information

Rocap Number(s): 28054-10537450-Caltrans
Heat Number(s): 10537450, 6214552205, 174316
Nut Mfg. Lot Number(s): 28125-6214552205
Washer Mfg. Lot Number(s): d4996
Bolt Specification: A325
Bolt Length(s):
Nut Specification: A563 DH
Washer Specification: F436
Finish: Mech Galv
Diameter/Size: 1" x 3"
Bolt Mfg. Lot Number: 28053-10537450
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 8

DIME Test ID: 2018-06-20-9-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/01/2018
Date Tested: 07/19/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
9A28054-105374501\"90301401.710A325Brian
UTM 400KIP
Temperature no data

Test 2 of 8

DIME Test ID: 2018-06-20-9-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 08/01/2018
Date Tested: 07/25/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
9A28125-62145522051\"93168414.43Nut ProofBrian
UTM 400KIP
Temperature 72 F

Test 3 of 8

DIME Test ID: 2018-06-20-9-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/01/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 9A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 28054-10537450
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size 1 in
Bolt Length 3 in
Gage Type Pass

Test 4 of 8

DIME Test ID: 2018-06-20-9-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 08/01/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 9A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 28125-6214552205
Finish Coating ASTM B695 - Mech Galv
Product Markings U DH3
Size 1 in
Gage Type NA

Test 5 of 8

DIME Test ID: 2018-06-20-9-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/01/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 9A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 28054-10537450
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 TC USA
Size 1 in
Bolt Length 3 in
Measurement Average 4.32 mils

Test 6 of 8

DIME Test ID: 2018-06-20-9-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/01/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 9A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 28125-6214552205
Finish Coating ASTM B695 - Mech Galv
Product Markings U DH3
Size 1 in
Bolt Length no data in
Measurement Average 4.93 mils

Test 7 of 8

DIME Test ID: 2018-06-20-9-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/01/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 9A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number D4996
Finish Coating ASTM B695 - Mech Galv
Product Markings P F436-3
Size 1 in
Bolt Length no data in
Measurement Average 2.28 mils

Test 8 of 8

DIME Test ID: 2018-06-20-9-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/01/2018
Date Tested: 07/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 9A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number D4996
Finish Coating ASTM B695 - Mech Galv
Product Markings P F436-3
Size 1 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 40.4
Spacing Ok