Print Report | Back to Sample Detail

Sample Record for 2026-09-16-66

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1002671 DEA: 09402704 EFIS: 0924000060 QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO--unknown
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-09-16-66
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/16/2026
Date that the sample was received by the laboratory/organization performing the testing: 10/09/2026
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: HOT PLANT

Material Information

Asphalt modifier supplier:
Performance Grade: PG 58-22
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test

DIME Test ID: 2026-09-16-66-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 10/30/2026
Date Tested: 10/28/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 65 C
Softening Point Sample 2 65 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test

DIME Test ID: 2026-09-16-66-2
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 10/30/2026
Date Tested: 10/28/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 43 0.1 mm

Test

DIME Test ID: 2026-09-16-66-3
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 10/30/2026
Date Tested: 10/28/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 2 mm
Final Dial reading (F1) 52 mm
Ball Penetration (P2) 3 mm
Final Dial reading (F2) 53 mm
Ball Penetration (P3) 2 mm
Final Dial reading (F3) 51 mm
Resilience 1 50 %
Resilience 2 50 %
Resilience 3 51 %
Average Resilience 50 %
Minutes Reaction no data