Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001169 DEA: 07314524 EFIS: 0722000300 COOP: 075283
QA Service Level: 2
DIST-CO-RTE-PM: 07---
Work Description: I-105 METRO Express Lanes Project
Location Description: LA-105 PM R0.6/R10.1, LA-110 PM R14.1/R16.6
Contractor Name: Flatiron-Myers (JV)
Contractor Address: Unknown
Resident Engineer: Joahnna Vergara Structure Rep.: James Holloway
DIME Sample ID: 2026-09-10-97
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/10/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/11/2026
The quantity of what the sample constitutes: 32.06 Tons
A brief description of the sample: 3/8 HMA Dike
From where was the sample collected: Manufacturer
Laboratory sample identification: 091026-ID10-HMA-1
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Sun Valley
DIME Test ID: 2026-09-10-97-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/14/2026
Date Tested: 09/11/2026
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4005 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5548.1 g
|
|
Mass of HMA Sample prior to ignition
|
1543.1 g
|
|
Corrected Asphalt Binder Content
|
4.77 %
|
|
Mass Loss
|
90.7 g
|
|
Mass of aggregate remaining after ignition
|
1452.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.88 %
|
|
Moisture Content
|
0.23 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|