Print Report | Back to Sample Detail

Sample Record for 2026-09-10-97

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001169 DEA: 07314524 EFIS: 0722000300 COOP: 075283 QA Service Level: 2
DIST-CO-RTE-PM: 07---
Work Description: I-105 METRO Express Lanes Project
Location Description: LA-105 PM R0.6/R10.1, LA-110 PM R14.1/R16.6
Contractor Name: Flatiron-Myers (JV)
Contractor Address: Unknown
Resident Engineer: Joahnna Vergara Structure Rep.: James Holloway

Sample Information

DIME Sample ID: 2026-09-10-97
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/10/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/11/2026
The quantity of what the sample constitutes: 32.06 Tons
A brief description of the sample: 3/8 HMA Dike
From where was the sample collected: Manufacturer
Laboratory sample identification: 091026-ID10-HMA-1
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Sun Valley

Material Information

HMA Type: Not Applicable
HMA Grading: 3/8 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2026-09-10-97-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/14/2026
Date Tested: 09/11/2026
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4005 g
Mass of the specimen and specimen basket assembly prior to ignition 5548.1 g
Mass of HMA Sample prior to ignition 1543.1 g
Corrected Asphalt Binder Content 4.77 %
Mass Loss 90.7 g
Mass of aggregate remaining after ignition 1452.4 g
Correction Factor (Percent by mass of HMA Specimen) 0.88 %
Moisture Content 0.23 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C