Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: YYZ
Contractor Address: 1234 address, Sacramento, CA 95824
Resident Engineer: RE_first RE_last Structure Rep.: SR_First SR_Last
DIME Sample ID: 2026-07-06-115
TL Number from the TL Form:
Sample Submitted By Organization: Stonemont Solutions, Incorporated
Sample Organization Contact: (970) 674-1148
Type of Sample: Informational
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/06/2026
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 150
A brief description of the sample: half inch HMA sample
From where was the sample collected: Source
Laboratory sample identification: 1360000571
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Stonemont Solutions
DIME Test ID: 2026-07-06-115-1
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Submitted By Organization: Stonemont Solutions, Incorporated
Organization Address: 128 North 6th Street, Suite A,
Organization City: Windsor
Organization State: CO
Organization Zipcode: 80550
Organization Email: jbeal@stonemont.com
Organization Phone: (970) 674-1148
Data has not been verified.
DIME Test ID: 2026-07-06-115-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Submitted By Organization: Stonemont Solutions, Incorporated
Organization Address: 128 North 6th Street, Suite A,
Organization City: Windsor
Organization State: CO
Organization Zipcode: 80550
Organization Email: jbeal@stonemont.com
Organization Phone: (970) 674-1148
Data has not been verified.
DIME Test ID: 2026-07-06-115-3
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Submitted By Organization: Stonemont Solutions, Incorporated
Organization Address: 128 North 6th Street, Suite A,
Organization City: Windsor
Organization State: CO
Organization Zipcode: 80550
Organization Email: jbeal@stonemont.com
Organization Phone: (970) 674-1148
Data has not been verified.
DIME Test ID: 2026-07-06-115-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Submitted By Organization: Stonemont Solutions, Incorporated
Organization Address: 128 North 6th Street, Suite A,
Organization City: Windsor
Organization State: CO
Organization Zipcode: 80550
Organization Email: jbeal@stonemont.com
Organization Phone: (970) 674-1148
Data has not been verified.
DIME Test ID: 2026-07-06-115-5
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Submitted By Organization: Stonemont Solutions, Incorporated
Organization Address: 128 North 6th Street, Suite A,
Organization City: Windsor
Organization State: CO
Organization Zipcode: 80550
Organization Email: jbeal@stonemont.com
Organization Phone: (970) 674-1148
Data has not been verified.
DIME Test ID: 2026-07-06-115-6
Test Method: CTM 321-0: New Test Method for Determination of Rutting Resistance Using High Temperature Indirect Tensile (HT-IDT) Strength of Asphalt Mixtures
Submitted By Organization: Stonemont Solutions, Incorporated
Organization Address: 128 North 6th Street, Suite A,
Organization City: Windsor
Organization State: CO
Organization Zipcode: 80550
Organization Email: jbeal@stonemont.com
Organization Phone: (970) 674-1148
Data has not been verified.
DIME Test ID: 2026-07-06-115-7
Test Method: ASTM D8225-19: Standard Test Method For Determination Of Cracking Tolerance Index Of Asphalt Mixture Using The Indirect Tensile Cracking Test At Intermediate Temperature
Submitted By Organization: Stonemont Solutions, Incorporated
Organization Address: 128 North 6th Street, Suite A,
Organization City: Windsor
Organization State: CO
Organization Zipcode: 80550
Organization Email: jbeal@stonemont.com
Organization Phone: (970) 674-1148
Data has not been verified.
DIME Test ID: 2026-07-06-115-8
Test Method: ASTM D8360-22: Standard Test Method for Determination of Rutting Tolerance Index of Asphalt Mixture Using the Ideal Rutting Test (Rutting Tolerance)
Submitted By Organization: Stonemont Solutions, Incorporated
Organization Address: 128 North 6th Street, Suite A,
Organization City: Windsor
Organization State: CO
Organization Zipcode: 80550
Organization Email: jbeal@stonemont.com
Organization Phone: (970) 674-1148