Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1002539 DEA: 042X7104 EFIS: 0425000144
QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL--unknown
Work Description: HM1 Pavement
Location Description: SOLANO COUNTY NEAR DIXON ON ROUTE 80 AT PEDRICK ROAD OVERCROSSING AND ON ROUTE 113 FROM ROUTE 12 TO 0.3 MILE SOUTH OF PARKWAY BOULEVARD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2026-09-11-72
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/11/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/14/2026
The quantity of what the sample constitutes: 2250-3000 Tons
A brief description of the sample: 3/4"WMA-Rap 15%
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Woodland
DIME Test ID: 2026-09-11-72-1
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 10/07/2026
Date Tested: 09/14/2026
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
No
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
10 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
88 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
79 %
|
|
Cumulative percent passing the #4 sieve
|
44 %
|
|
Cumulative percent passing the #8 sieve
|
29 %
|
|
Cumulative percent passing the #16 sieve
|
20 %
|
|
Cumulative percent passing the #30 sieve
|
15 %
|
|
Cumulative percent passing the #50 sieve
|
10 %
|
|
Cumulative percent passing the #100 sieve
|
8 %
|
|
Cumulative percent passing the #200 sieve
|
5.7 %
|
DIME Test ID: 2026-09-11-72-2
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/07/2026
Date Tested: 09/14/2026
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Corrected Asphalt Binder Content
|
4.87 %
|
|
Mass of HMA Sample prior to ignition
|
2074.7 g
|
|
Mass Loss
|
119 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.75 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.12 %
|
|
Test Temperature
|
482 C
|
DIME Test ID: 2026-09-11-72-3
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/07/2026
Date Tested: 09/14/2026
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Specific Gravity for Sample 1
|
2.49
|
|
Theoretical maximum density at 25°C (77°F)
|
2483 kg/m^3
|