Sample Record for 2026-09-25-30
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001613 DEA: 060V6104 EFIS: 0616000222
QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-119-28.2/31.3
Work Description: HMA (TYPE A), RCP, CLASS 2 AB, ROADWAY EXC, AND MODIFYING SIGNAL.
Location Description: KERN COUNTY IN AND NEAR BAKERSFIELD FROM 0.1 MILE WEST OF ASHE ROAD TO ROUTE 119/99 SEPARATION
Contractor Name: Griffith Company (Austin Fitch)
Contractor Address: 1128 Carrier Parkway, Bakersfield ,CA 93308
Resident Engineer: Mandeep Chahal Structure Rep.: Albert Heredia
Sample Information
DIME Sample ID: 2026-09-25-30
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Sample Organization Contact: 661-549-8281
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 09/25/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/20/2026
The quantity of what the sample constitutes: Structural Concrete Retaining Wall
A brief description of the sample: structural concrete
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: metro, Bakersfield
Material Information
The concrete mix design number: metro
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Sampled at Belt Cut
Concrete batch plant: Metro Bakersfield
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test
DIME Test ID: 2026-09-25-30-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 09/30/2026
Date Tested: 09/30/2026
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
2890 psi
|
|
Maximum load on cylinder 1
|
36040 lb
|
|
Maximum load on cylinder 2
|
37010 lb
|
|
Maximum load on cylinder 3
|
35930 lb
|
|
Compressive strength of cylinder 1
|
2867.1 psi
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Compressive strength of cylinder 2
|
2944.3 psi
|
|
Compressive strength of cylinder 3
|
2858.4 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
5
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
5 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test
DIME Test ID: 2026-09-25-30-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 10/02/2026
Date Tested: 10/02/2026
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
3050 psi
|
|
Maximum load on cylinder 1
|
38130 lb
|
|
Maximum load on cylinder 2
|
40560 lb
|
|
Maximum load on cylinder 3
|
36480 lb
|
|
Compressive strength of cylinder 1
|
3033.4 psi
|
|
Type of fracture pattern of cylinder 1
|
4
|
|
Compressive strength of cylinder 2
|
3226.7 psi
|
|
Compressive strength of cylinder 3
|
2902.1 psi
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Type of fracture pattern of cylinder 3
|
4
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|