Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001609 DEA: 040AA244 EFIS: 0419000455
QA Service Level: 1
DIST-CO-RTE-PM: 04-CC, -680-R0.0/R7.7
Work Description: INDIVIDUAL SLAB REPLACEMENT, COLD PLAN AC PVMT, GRIND EXIST CONC PVMT.
Location Description: CONTRA COSTA COUNTY IN SAN RAMON AND DANVILLE FROM THE ALAMEDA COUNTY LINE TO 0.2 MILE NORTH OF DIABLO ROAD UNDERCROSSING
Contractor Name: Bay Cities Paving and Grading
Contractor Address: 1450 Civic Ct., Bldg B #400, Concord, CA 94520
Resident Engineer: Eddie Dike Structure Rep.: Unknown
DIME Sample ID: 2026-09-22-33
TL Number from the TL Form: CPL092226-2
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: JMF Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/22/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/28/2026
The quantity of what the sample constitutes: 2 cans
A brief description of the sample: 2 cans of Rubberized Binder
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan- Pleasanton
Asphalt modifier supplier: Pacific Northwest
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2026-09-22-33-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/29/2026
Date Tested: 09/29/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: CONE PENETRATION
Test Result Compliance: complies
Additional Comments When Verified:
|
Determination
|
Unworked Penetration
|
|
Unworked Penetration
|
34 0.1 mm
|
DIME Test ID: 2026-09-22-33-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/29/2026
Date Tested: 09/29/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: SOFTENING POINT
Test Result Compliance: complies
Additional Comments When Verified:
|
ASTM Thermometer used?
|
C
|
|
Softening Point Sample 1
|
63 C
|
|
Softening Point Sample 2
|
63 C
|
|
Bath Liquid
|
freshly boiled distilled water
|
|
Minutes Reaction
|
no data
|
DIME Test ID: 2026-09-22-33-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/29/2026
Date Tested: 09/29/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: RESILIENCE REBOUND
Test Result Compliance: complies
Additional Comments When Verified:
|
Temperature
|
25 C
|
|
Ball Penetration (P1)
|
5 mm
|
|
Final Dial reading (F1)
|
71 mm
|
|
Ball Penetration (P2)
|
2 mm
|
|
Final Dial reading (F2)
|
68 mm
|
|
Ball Penetration (P3)
|
4 mm
|
|
Final Dial reading (F3)
|
71 mm
|
|
Resilience 1
|
34 %
|
|
Resilience 2
|
34 %
|
|
Resilience 3
|
33 %
|
|
Average Resilience
|
34 %
|
|
Minutes Reaction
|
no data
|