Print Report | Back to Sample Detail

Sample Record for 2026-09-11-56

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000511 DEA: 06487404 EFIS: 0616000029 QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-35.8/37.1
Work Description: Caldwell Interchange SR99/Ave280 (Visalia) - Replace Bridge Structures and Construct Roundabouts.
Location Description: TULARE COUNTY IN AND NEAR VISALIA FROM 0.6 MILE SOUTH OF AVENUE 280 OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 280 OVERCROSSING
Contractor Name: Granite Construction Company (Karen Cervantes)
Contractor Address: 2716 Granite Court, Fresno, CA 93706
Resident Engineer: Alberto Lopez Structure Rep.: Martin Garcia

Sample Information

DIME Sample ID: 2026-09-11-56
TL Number from the TL Form:
Sample Submitted By Organization: Surecast West
Sample Organization Contact: (951) 491-9506
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 09/11/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/14/2026
The quantity of what the sample constitutes: 9.50 CY
A brief description of the sample: TYPE II /V
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CEMEX -REDLANDS

Material Information

The concrete mix design number: 1610974
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 32136290
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: CONCRETE SAMPLE FROM WHEELBARROW
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-09-11-56-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 09/25/2026
Date Tested: 09/23/2026
Submitted By Organization: Surecast West
Organization Address: 8203 Alabama Street,
Organization City: Redlands
Organization State: CA
Organization Zipcode: 92373
Organization Email: cody@surecastwest.com
Organization Phone: (951) 491-9506
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 4 in^2
Cross sectional area of cylinder 2 4 in^2
Cross sectional area of cylinder 3 4 in^2
Compressive strength (to nearest 10 psi) 5440 psi
Maximum load on cylinder 1 69190 lb
Maximum load on cylinder 2 67560 lb
Maximum load on cylinder 3 68290 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 12 days
Age of specimen in hours no data0 hours

Test

DIME Test ID: 2026-09-11-56-2
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 09/25/2026
Date Tested: 09/11/2026
Submitted By Organization: Surecast West
Organization Address: 8203 Alabama Street,
Organization City: Redlands
Organization State: CA
Organization Zipcode: 92373
Organization Email: cody@surecastwest.com
Organization Phone: (951) 491-9506
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 3.75 inch

Test

DIME Test ID: 2026-09-11-56-3
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 09/25/2026
Date Tested: 09/11/2026
Submitted By Organization: Surecast West
Organization Address: 8203 Alabama Street,
Organization City: Redlands
Organization State: CA
Organization Zipcode: 92373
Organization Email: cody@surecastwest.com
Organization Phone: (951) 491-9506
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 87 F

Test

DIME Test ID: 2026-09-11-56-4
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 09/25/2026
Date Tested: 09/11/2026
Submitted By Organization: Surecast West
Organization Address: 8203 Alabama Street,
Organization City: Redlands
Organization State: CA
Organization Zipcode: 92373
Organization Email: cody@surecastwest.com
Organization Phone: (951) 491-9506
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample 1610974
Volume of the measure 0.25 ft^3
Density of concrete 147.2 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content no data