Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1002490 DEA: 042X7404 EFIS: 0425000147
QA Service Level: 1
DIST-CO-RTE-PM: 04-SCL--unknown
Work Description: COLD PLANE, HMA(TYPE A), RHMA(OGFC) & HIGH
Location Description: In SANTA CLARA COUNTY NEAR LOS GATOS FROM SANTA CLARA COUNTY LINE TO 0.1 MILE NORTH OF HEBARD ROAD
Contractor Name: Craig Flowers (Granite Construction Company)
Contractor Address: PO Box 6744, Santa Barbara, CA 93160
Resident Engineer: Farsipour naghibi Structure Rep.: Unknown
DIME Sample ID: 2026-09-16-42
TL Number from the TL Form: Sacramento Caltrans Lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: High Friction Surface Treatment
Sample Taken Date: 09/16/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/17/2026
The quantity of what the sample constitutes: 1 tanker
A brief description of the sample: 1 gallon can / HFST RESIN
From where was the sample collected: Source
Laboratory sample identification: 000228KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2026-09-16-42-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 09/30/2026
Date Tested: 09/23/2026
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Gel Time ASTM C881: 14.59 min.
Cure Rate ASTM D1640: 122 min.
Accepted supplier's results.
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2026-09-16-42-2
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 09/30/2026
Date Tested: 09/23/2026
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted supplier's results.
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
6
|
|
Conditioning procedure
|
18/25/50+5/70
|
|
Speed of testing
|
0.45 in/min
|
|
Sample 1 Width
|
0.497 in
|
|
Sample 1 Ultimate strength
|
4106.1 psi
|
|
Sample 1 Thickness
|
0.144 in
|
|
Sample 1 Area
|
0.0716 in^2
|
|
Sample 1 Ultimate Strength Actual
|
294 lbs
|
|
Sample 1 percent elongation
|
43 %
|
|
Sample 1 Time
|
no data0 MM:SS
|
|
Sample 2 Width
|
0.496 in
|
|
Sample 2 Thickness
|
0.138 in
|
|
Sample 2 Area
|
0.0684 in^2
|
|
Sample 2 Ultimate strength
|
4152 psi
|
|
Sample 2 Ultimate Strength Actual
|
284 lbs
|
|
Sample 2 percent elongation
|
51 %
|
|
Sample 2 Time
|
no data0 MM:SS
|
|
Sample 3 Width
|
0.5 in
|
|
Sample 3 Thickness
|
0.147 in
|
|
Sample 3 Area
|
0.0735 in^2
|
|
Sample 3 Ultimate strength
|
4081.6 psi
|
|
Sample 3 Ultimate Strength Actual
|
300 lbs
|
|
Sample 3 percent elongation
|
45 %
|
|
Sample 3 Time
|
no data0 MM:SS
|
|
Sample 4 Width
|
0.496 in
|
|
Sample 4 Thickness
|
0.141 in
|
|
Sample 4 Area
|
0.0699 in^2
|
|
Sample 4 Ultimate strength
|
4134.5 psi
|
|
Sample 4 Ultimate Strength Actual
|
289 lbs
|
|
Sample 4 percent elongation
|
45 %
|
|
Sample 4 Time
|
no data0 MM:SS
|
|
Sample 5 Width
|
0.496 in
|
|
Sample 5 Thickness
|
0.138 in
|
|
Sample 5 Area
|
0.0684 in^2
|
|
Sample 5 Ultimate strength
|
4166.7 psi
|
|
Sample 5 Ultimate Strength Actual
|
285 lbs
|
|
Sample 5 percent elongation
|
49 %
|
|
Sample 5 Time
|
no data0 MM:SS
|
|
Sample 6 Width
|
0.495 in
|
|
Sample 6 Thickness
|
0.146 in
|
|
Sample 6 Area
|
0.0723 in^2
|
|
Sample 6 Ultimate strength
|
4135.5 psi
|
|
Sample 6 Ultimate Strength Actual
|
299 lbs
|
|
Sample 6 percent elongation
|
43 %
|
|
Sample 6 Time
|
no data0 MM:SS
|
|
Ultimate Strength Average
|
4129 psi
|
|
Percent Elongation Average
|
46 %
|