Print Report | Back to Sample Detail

Sample Record for 2026-09-18-40

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000710 DEA: 100P9244 EFIS: 1023000226 QA Service Level: 1
DIST-CO-RTE-PM: 10-MPA-140-42.0/42.7
Work Description: Fergusen Slide Rock Avalanche Shed
Location Description: Mariposa County, along Route 140 in the Merced River canyon, about 8 miles east of Briceburg and 7.6 miles west of El Portal.
Contractor Name: Myers and Sons Construction, LLC/Ralph L. Wadsworth
Contractor Address: 2554 Millcreek Drive, Sacramento, CA 95833
Resident Engineer: Jonathan Ngai Structure Rep.: Sai Kasaraneni

Sample Information

DIME Sample ID: 2026-09-18-40
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 09/18/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/23/2026
The quantity of what the sample constitutes: 40- Various Lengths
A brief description of the sample: 1" 150ksi All-Thread Bar
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Engineering-SD

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type:
Rebar Size:
Nut Specification for Threaded Bar: ASTM A29/A108
System Manufacturer: Williams Form Engineering San Diego
Epoxy Coating Color: Purple
Threaded Bar Application:
Coating Standards: ASTM A934 epoxy
Bar Heat Number(s): 58053048
Nut Heat Number(s): 1000127644
Bar Lot Number:
Nut Lot Number: 26J1D
Coupler Heat Number(s):
Coupler Grade:

Test Results

Test

DIME Test ID: 2026-09-18-40-1
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 09/30/2026
Date Tested: 09/30/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples 2
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
11580530480.8517590013970070000A722 Bar and NutAtlas
21580530480.85170400142600733A722 Bar and NutAtlas
Temperature 0 f
UTM NA