Print Report | Back to Sample Detail

Sample Record for 2026-09-20-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001573 DEA: 060X2904 EFIS: 0618000050 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-33-13.9/16.7
Work Description: HMA (TYPE A), RDWY EXC, CL 2 AB, CURB RAMPS AND MOBILIZATION.
Location Description: FRESNO COUNTY IN AND NEAR COALINGA FROM ENTERPRISE PARKWAY TO LOS GATOS CREEK SOUTH CHANNEL BRIDGE
Contractor Name: Cal Valley Construction, Inc. (Chris Grimm)
Contractor Address: Unknown
Resident Engineer: Din Dadawalla Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-09-20-3
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/20/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/20/2026
The quantity of what the sample constitutes: 155 Tons
A brief description of the sample: 3/4 HMA
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Coalinga

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 3
Sublot number: 8
HMA Mix Number:
Binder content (%): 5.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2026-09-20-3-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/28/2026
Date Tested: 09/22/2026
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 341-3953
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 2931 g
Mass of the specimen and specimen basket assembly prior to ignition 5078.6 g
Corrected Asphalt Binder Content 5.12 %
Mass of HMA Sample prior to ignition 2147.6 g
Mass Loss 139.8 g
Mass of aggregate remaining after ignition 2007.8 g
Correction Factor (Percent by mass of HMA Specimen) 1.25 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 482 C