Print Report | Back to Sample Detail

Sample Record for 2026-09-21-13

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1002572 DEA: 061H9704 EFIS: 0625000105 QA Service Level: 1
DIST-CO-RTE-PM: 06-MAD-152-R0.0/15.5
Work Description: MADERA COUNTY SLAB REPLACEMENT WITH DIGOUTS ON SR 59, 152. Cold plane AC, remove concrete pavement and place with HMA and RHMA.
Location Description: CONSTRUCTION ON STATE HIGHWAY IN MADERA COUNTY NEAR CHOWCHILLA FROM ROUTE 59/152 SEPARATION TO 0.1 MILE WEST OF ROUTE 99/152 SEPARATION.
Contractor Name: Granite Construction Company (Jorge Velazquez)
Contractor Address: Unknown
Resident Engineer: Alaa Ghoneim Structure Rep.: None None

Sample Information

DIME Sample ID: 2026-09-21-13
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/21/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/22/2026
The quantity of what the sample constitutes: 8 Boxes, 1 Bag
A brief description of the sample: 1/2 RHMA PG 64-16
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Santa Fe Aggregate Winton

Material Information

HMA Type: OGFC
HMA Grading: 1/2 inch
Lot number: 3
Sublot number: 9
HMA Mix Number:
Binder content (%): 8.0
Virgin binder PG: PG 64-16
Design binder PG: PG 64-16
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2026-09-21-13-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/28/2026
Date Tested: 09/22/2026
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 341-3953
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 2930.6 g
Mass of the specimen and specimen basket assembly prior to ignition 4532.9 g
Corrected Asphalt Binder Content 8.06 %
Mass of HMA Sample prior to ignition 1602.3 g
Mass Loss 130.6 g
Mass of aggregate remaining after ignition 1471.7 g
Correction Factor (Percent by mass of HMA Specimen) -0.09 %
Moisture Content no data0 %
Temperature Compensation Factor 0.18 %
Test Temperature 538 C