Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2025-06-03-113
TL Number from the TL Form:
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Asphalt Modifier
Sample Taken Date: 06/03/2025
Date that the sample was received by the laboratory/organization performing the testing: 08/26/2026
The quantity of what the sample constitutes: JMF Verification and OBC Determination
A brief description of the sample: Raffex 120 ACB Extender Oil
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tricor Refining (Bakersfield, CA)
DIME Test ID: 2025-06-03-113-1
Test Method: ASTM D445-14: Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) (Kinematic Viscosity)
Verified Date: 09/28/2026
Date Tested: 06/03/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
|
First Kinematic Viscosity
|
no data
|
|
Second Kinematic Viscosity
|
no data
|
|
Kinematic Viscosity
|
27 m2/s
|
|
Dynamic Viscosity
|
no data
|
DIME Test ID: 2025-06-03-113-2
Test Method: ASTM D92-12b: Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester (Flash Point)
Verified Date: 09/28/2026
Date Tested: 06/03/2025
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Ambient Barometric Pressure unit?
|
mm Hg
|
|
Corrected Flash Point
|
213 C
|