Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000121 DEA: 041Q8204 EFIS: 0418000341
QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-101-25.6/26.1
Work Description: SF 101-Roadway Rehab 3R
Location Description: Route 101 in San Francisco County
Contractor Name: FBD VANGUARD CONSTRUCTION, INC.
Contractor Address: 550 Greenville Road, Livermore, CA 94550
Resident Engineer: Tom Robinson Structure Rep.: ABBAS Iranmanesh
DIME Sample ID: 2026-09-19-4
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 09/19/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/21/2026
The quantity of what the sample constitutes: 450 cy
A brief description of the sample: Cylinders
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard Pier 94
The concrete mix design number: HE4X20BM
The truck number from where the sample was collected: 14
The batch plant ticket number from where the sample was collected: 169
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2026-09-19-4-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/29/2026
Date Tested: 09/29/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: compressive strength > 7000 psi, compression strength testing machine capacity is 7000 psi only
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
7000 psi
|
|
Maximum load on cylinder 1
|
87990 lb
|
|
Maximum load on cylinder 2
|
87990 lb
|
|
Maximum load on cylinder 3
|
87990 lb
|
|
Compressive strength of cylinder 1
|
7000.0 psi
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Compressive strength of cylinder 2
|
7000.0 psi
|
|
Compressive strength of cylinder 3
|
7000 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
10 days
|
|
Age of specimen in hours
|
no data0 hours
|