Print Report | Back to Sample Detail

Sample Record for 2026-09-19-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000121 DEA: 041Q8204 EFIS: 0418000341 QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-101-25.6/26.1
Work Description: SF 101-Roadway Rehab 3R
Location Description: Route 101 in San Francisco County
Contractor Name: FBD VANGUARD CONSTRUCTION, INC.
Contractor Address: 550 Greenville Road, Livermore, CA 94550
Resident Engineer: Tom Robinson Structure Rep.: ABBAS Iranmanesh

Sample Information

DIME Sample ID: 2026-09-19-3
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 09/19/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/21/2026
The quantity of what the sample constitutes: 450 cy
A brief description of the sample: Cylinders
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vanguard Pier 94

Material Information

The concrete mix design number: HE4X20BM
The truck number from where the sample was collected: 175
The batch plant ticket number from where the sample was collected: 111
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-09-19-3-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/29/2026
Date Tested: 09/29/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: compressive strength > 7000 psi, compression strength testing machine capacity is 7000 psi only
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 7000 psi
Maximum load on cylinder 1 87990 lb
Maximum load on cylinder 2 87990 lb
Maximum load on cylinder 3 87990 lb
Compressive strength of cylinder 1 7000.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 7000.0 psi
Compressive strength of cylinder 3 7000 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 10 days
Age of specimen in hours no data0 hours