Print Report | Back to Sample Detail

Sample Record for 2026-09-17-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000403 DEA: 120K91U4 EFIS: 1222000031 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-91-R9.2/R11.4
Work Description: CONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location Description: ORANGE COUNTY IN ANAHEIM FROM 0.9 MILE WEST TO 1.3 MILES EAST OF LAKEVIEW AVENUE OVERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 16700 Valley View Avenue Suite 300
Resident Engineer: Steve Kinaly Structure Rep.: Wei-Jen Lee

Sample Information

DIME Sample ID: 2026-09-17-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 09/17/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/18/2026
The quantity of what the sample constitutes: 64 Headed Bars (Lot 1)
A brief description of the sample: #9 ASTM A706 Gr 60 bar with type 150 head
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Headed Reinforcement Corporation (HRC)

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 9014206
Head Manufacturer Lot Number(s): 400003476521
Rebar Size: #9
Headed Bar Model Name: HRC 150
Size of Head: Full Size - 9x
Head Connection Type: Friction Weld
Head Shape: Circular
Rebar Manufacturer: CMC Steel Arizona
Head Manufacturer: Nucor
Head Fabricator: Headed Reinforcement Corp
Material Standard Code: ASTM A706
Headed Bar Unique ID: 9FW-17-04

Test Results

Test

DIME Test ID: 2026-09-17-6-1
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 09/25/2026
Date Tested: 09/25/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 4
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
118091081000Broke at HeadKleinfelder
119869098500Ok NeckingKleinfelder
119984099840Ok NeckingKleinfelder
119932099320Ok NeckingKleinfelder
Temperature 0 f
UTM NA