Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 209698 DEA: 072332E4 EFIS: 0700000391 COOP: 0705187
QA Service Level: 2
DIST-CO-RTE-PM: 07-LA-I-5-45.4/54
Work Description: Addition of 14 miles of HOV lanes in both directions would extend existing carpool lanes on the I- 5 in San Fernando Valley to Santa Clarita Valley
Location Description: The I-5 North Capacity Enhancements Project focuses on improvements to the I-5 freeway from cities of Santa Clarita and Castaic, beginning at the SR-14 interchange to Parker Rd.
Contractor Name: OHLA USA
Contractor Address: Unknown
Resident Engineer: James Shih Structure Rep.: Chanh Tong
DIME Sample ID: 2026-08-06-109
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Plant Services, Unit 1841
Sample Organization Contact: (562) 345-3126
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 08/06/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/06/2026
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4" Aggregate
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Sun Valley
Source Identification (SMARA, name of Pit or Job Site): 91-19-0035
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Conveyor Belt
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2026-08-06-109-1
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Submitted By Organization: CT D07 - Plant Services, Unit 1841
Organization Address: 13230 East Firestone Boulevard, Suite G,
Organization City: Santa Fe Springs
Organization State: CA
Organization Zipcode: 90670
Organization Email: victor.zengler@dot.ca.gov
Organization Phone: (562) 345-3126
Data has not been verified.
DIME Test ID: 2026-08-06-109-2
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Submitted By Organization: CT D07 - Plant Services, Unit 1841
Organization Address: 13230 East Firestone Boulevard, Suite G,
Organization City: Santa Fe Springs
Organization State: CA
Organization Zipcode: 90670
Organization Email: victor.zengler@dot.ca.gov
Organization Phone: (562) 345-3126
Data has not been verified.