Print Report | Back to Sample Detail

Sample Record for 2026-09-04-23

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001360 DEA: 09374804 EFIS: 0918000020 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-115.0
Work Description: BUILDING WORK AND PLACE HMA (TYPE A).
Location Description: INYO COUNTY IN BISHOP AT THE DISTRICT OFFICE AT 500 SOUTH MAIN STREET
Contractor Name: BOWE CONTRACTORS INC.
Contractor Address: 609 Bailey Ct, Tehachapi, CA 93561
Resident Engineer: David Carruba Structure Rep.: Alejandrino Naime

Sample Information

DIME Sample ID: 2026-09-04-23
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 09/04/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/07/2026
The quantity of what the sample constitutes: 5cy
A brief description of the sample: 6 PCC Cylinders 4x8
From where was the sample collected: Job Site
Laboratory sample identification: PCC-07
Structure unique identifier:
Structure name: Lab Slab on Grade
The fabricator/manufacturer/facility name: 7/11 Bishop

Material Information

The concrete mix design number: 718216A6
The truck number from where the sample was collected: 83992
The batch plant ticket number from where the sample was collected: 984402
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: 5cy into Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-09-04-23-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 10/06/2026
Date Tested: 10/05/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: PCC-07
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4340 psi
Maximum load on cylinder 1 54580 lb
Maximum load on cylinder 2 55600 lb
Maximum load on cylinder 3 53480 lb
Compressive strength of cylinder 1 4342.1 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 4423.2 psi
Compressive strength of cylinder 3 4254.6 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 31 days
Age of specimen in hours no data0 hours