Print Report | Back to Sample Detail

Sample Record for 2026-08-31-35

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001686 DEA: 11430264 EFIS: 1118000083 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-94,188-15.2/65.3,0.0/1.9
Work Description: DRAINAGE RESTORATION, ADA CURB RAMPS & COMPLETE STREET.
Location Description: SAN DIEGO COUNTY ABOUT 6 MILES EAST OF LEMON GROVE ON ROUTE 94 FROM SWEETWATER RIVER BRIDGE TO AVENUE DE ROBLES VERDES NEAR MANZANITA AND ON ROUTE 188 FROM MEXICO BORDER NEAR TECATE TO ROUTE 94.
Contractor Name: LB Civil Construction
Contractor Address: 324 East Valley Parkway, Escondido, CA 92025
Resident Engineer: Daniel Assefa Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-08-31-35
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/31/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/06/2026
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: Daily Production
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: MM Lakeside

Material Information

HMA Type: Type A HMA
HMA Grading: 1-1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 21517070
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier: Valero
RAP content (%): 0
WMA Additives: No
Antistrip type:

Test Results

Test

DIME Test ID: 2026-08-31-35-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/24/2026
Date Tested: 09/11/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 10199 grams
Mass of oven-dry sample in air for Sample 1 4088.8 grams
Mass of container filled with the sample and water for Sample 1 12683.9 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.549
Theoretical maximum density at 25°C (77°F) 2541.6 kg/m^3

Test

DIME Test ID: 2026-08-31-35-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/14/2026
Date Tested: 09/11/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies 3.88%, min required is 3.85%.
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3924.5 g
Mass of the specimen and specimen basket assembly prior to ignition 7967.5 g
Mass of HMA Sample prior to ignition 4043 g
Corrected Asphalt Binder Content 3.88 %
Mass Loss 167.4 g
Mass of aggregate remaining after ignition 3875.6 g
Correction Factor (Percent by mass of HMA Specimen) 0.26 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test

DIME Test ID: 2026-08-31-35-3
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 09/14/2026
Date Tested: 09/11/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Failing 1", 3/4", 3/8", #4. and #8 screens
Test Result Compliance: does not comply
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) -0.5 %
Aggregate correction factor for the 1 in. sieve (% passing) 1.2 %
Aggregate correction factor for the 3/4 in. sieve (% passing) -0.3 %
Aggregate correction factor for the 1/2 in. sieve (% passing) 0.1 %
Aggregate correction factor for the 3/8 in. sieve (% passing) -2.6 %
Aggregate correction factor for the #4 sieve (% passing) -3 %
Aggregate correction factor for the #8 sieve (% passing) -2.4 %
Aggregate correction factor for the #16 sieve (% passing) -2 %
Aggregate correction factor for the #30 sieve (% passing) -1.5 %
Aggregate correction factor for the #50 sieve (% passing) -0.5 %
Aggregate correction factor for the #100 sieve (% passing) 0.3 %
Aggregate correction factor for the #200 sieve (% passing) 0.6 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 81 %
Cumulative percent passing the 3/4 in. sieve 70 %
Cumulative percent passing the 1/2 in. sieve 53 %
Cumulative percent passing the 3/8 in. sieve 40 %
Cumulative percent passing the #4 sieve 30 %
Cumulative percent passing the #8 sieve 23 %
Cumulative percent passing the #16 sieve 15 %
Cumulative percent passing the #30 sieve 10 %
Cumulative percent passing the #50 sieve 7 %
Cumulative percent passing the #100 sieve 4 %
Cumulative percent passing the #200 sieve 3.1 %

Test

DIME Test ID: 2026-08-31-35-5
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 10/07/2026
Date Tested: 10/02/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Retest, does not comply
Test Result Compliance: does not comply
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) -0.5 %
Aggregate correction factor for the 1 in. sieve (% passing) 1.2 %
Aggregate correction factor for the 3/4 in. sieve (% passing) -0.3 %
Aggregate correction factor for the 1/2 in. sieve (% passing) 0.1 %
Aggregate correction factor for the 3/8 in. sieve (% passing) -2.6 %
Aggregate correction factor for the #4 sieve (% passing) -3 %
Aggregate correction factor for the #8 sieve (% passing) -2.4 %
Aggregate correction factor for the #16 sieve (% passing) -2 %
Aggregate correction factor for the #30 sieve (% passing) -1.5 %
Aggregate correction factor for the #50 sieve (% passing) -0.5 %
Aggregate correction factor for the #100 sieve (% passing) 0.3 %
Aggregate correction factor for the #200 sieve (% passing) 0.6 %
Cumulative percent passing the 2 in. sieve 101 %
Cumulative percent passing the 1 1/2 in. sieve 98 %
Cumulative percent passing the 1 in. sieve 64 %
Cumulative percent passing the 3/4 in. sieve 46 %
Cumulative percent passing the 1/2 in. sieve 37 %
Cumulative percent passing the 3/8 in. sieve 26 %
Cumulative percent passing the #4 sieve 19 %
Cumulative percent passing the #8 sieve 15 %
Cumulative percent passing the #16 sieve 11 %
Cumulative percent passing the #30 sieve 7 %
Cumulative percent passing the #50 sieve 5 %
Cumulative percent passing the #100 sieve 3 %
Cumulative percent passing the #200 sieve 2.5 %

Test

DIME Test ID: 2026-08-31-35-6
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 09/28/2026
Date Tested: 09/25/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of Cores 2
Core ID 1
Dry Weight 3911.3 grams
Parrafin Coated Weight 3951.4 grams
Coated Weight in Water 2291.7 grams
Theoretical Maximum Density 2.549
Core 2 ID 2
Dry Weight 2 3884.9 grams
Parrafin Coated Weight 2 3924.7 grams
Coated Weight in Water 2 2268.4 grams