Print Report | Back to Sample Detail

Sample Record for 2026-09-02-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212900 DEA: 051G6804 EFIS: 0515000063 QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-101-16.2-20.3
Work Description: US 101 PISMO CONGESTION RELIEF PROJECT
Location Description: IN SAN LUIS OBISPO COUNTY IN PSMO BEACH FROM PISMO OVERHEAD TO 0.5 MILE NORTH OF SHELL BEACH ROAD UC
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 351 North Blosser Road, Santa Maria, CA 93458
Resident Engineer: Philip Gaston Structure Rep.: Sal Heredia

Sample Information

DIME Sample ID: 2026-09-02-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 09/02/2026
Date that the sample was received by the laboratory/organization performing the testing: 09/04/2026
The quantity of what the sample constitutes: 96 hoops
A brief description of the sample: ASTM A706 #6 x 3' 2" dia. welded hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC Rebar San Bernardino

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 4160266
Hoop Manufacturer Lot Number(s): Lot 1
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #6
Diameter of Hoop: 3'-2"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: CMC Arizona
Welding Company: CMC Rebar San Bernardino
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test

DIME Test ID: 2026-09-02-2-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 09/14/2026
Date Tested: 09/14/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 4
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1160.4445020102000ok neckingKleinfelder
2160.444371099500ok neckingKleinfelder
3160.444249096500ok neckingKleinfelder
4160.444309098000ok neckingKleinfelder
UTM NA
Temperature 0 f