Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1002359 DEA: 070Y1204 EFIS: 0724000133
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-405-VAR
Work Description: RTE 405 PAVEMENT REHAB - INDIVIDUAL SLAB REPLACEMENT (RSC), LEAN CONCRETE BASE RAPID SETTING, BASE BOND BREAKER, RHMA-G, SLURRY SEAL, COLD PLANE, DRILL & BOND DOWELS, PAVEMENT DELINEATION, MODIFYING RAMP METERING & SIGNAL/LIGHTING SYSTEMS (166TH ST UC TO MANCHESTER BLVD OC)
Location Description:
Contractor Name: RV Concrete
Contractor Address: 605 E Commercial Street, Anaheim, CA 92801
Resident Engineer: Khanh-Van Nguyen Structure Rep.: Unknown
DIME Sample ID: 2026-08-11-92
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 08/11/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/18/2026
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Binder Sample
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt-Irwindale
Performance Grade: PG 64-16
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier: n/a
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
HMA Type: n/a
HMA Supplier Mix ID Number: n/a
DIME Test ID: 2026-08-11-92-3
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/02/2026
Date Tested: 09/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
Original binder
|
|
Phase Angle (δ) (for the 10 cycles)
|
87.5 degree
|
|
Dynamic Shear, G*/sin(δ)
|
1.46 kPa
|
DIME Test ID: 2026-08-11-92-4
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/02/2026
Date Tested: 09/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
RTFO residue
|
|
Phase Angle (δ) (for the 10 cycles)
|
84.2 degree
|
|
Dynamic Shear, G*/sin(δ)
|
4.11 kPa
|
DIME Test ID: 2026-08-11-92-6
Test Method: AASHTO T44-23: Standard Method of Test for Solubility of Bituminous Materials
Verified Date: 09/02/2026
Date Tested: 09/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Was test performed on residue from distillation or evaporation?
|
NA
|
|
Soluble, percent
|
99.54 %
|
|
Insoluble, percent
|
0.46 %
|
DIME Test ID: 2026-08-11-92-1
Test Method: AASHTO T228-22: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Verified Date: 09/02/2026
Date Tested: 09/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
DIME Test ID: 2026-08-11-92-5
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 09/02/2026
Date Tested: 09/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
|
Time of test
|
9:25 HH:MM
|
|
Test Temperature
|
135 C
|
|
Speed
|
100 rpm
|
|
Spindle size
|
21 in
|
|
Torque
|
73.8 %
|
|
Viscosity reading #1 (A)
|
0.366 Pa-s
|
|
Viscosity reading #2 (B)
|
0.37 Pa-s
|
|
Viscosity reading #3 (C)
|
0.372 Pa-s
|
|
Average viscosity
|
0.369 Pa-s
|
DIME Test ID: 2026-08-11-92-2
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 09/02/2026
Date Tested: 09/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is mass change based on one or two containers?
|
Two
|
|
Is mass change correction factor needed?
|
Yes
|
|
Any material loss from containers during heating process/testing?
|
No
|
|
Mass of container #1 before test (m1i)
|
203.346 grams
|
|
Mass of container #2 before test (m2i)
|
202.654 grams
|
|
Mass of container #1 after test (m1f)
|
203.299 grams
|
|
Mass of container #2 after test (m2f)
|
202.607 grams
|
|
Average mass change
|
-0.128 percent
|
|
Mass of empty container #1
|
168.212 grams
|
|
Mass of empty container #2
|
167.469 grams
|
|
Mass correction factor
|
0.006
|
DIME Test ID: 2026-08-11-92-7
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 09/18/2026
Date Tested: 09/14/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is a normal test obtainable?
|
Yes
|
|
Number of replicates tested
|
One
|
|
Ductility of test #1 (D1)
|
150 cm
|
|
Ductility of sample
|
150 cm
|
DIME Test ID: 2026-08-11-92-8
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 09/18/2026
Date Tested: 09/16/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Maximum test bath temperature at 240 S
|
0.0 C
|
|
Minimum test bath temperature at 240 S
|
0.0 C
|
|
Estimated Stiffness Modulus 8.0 s
|
0.000 MPa
|
|
Estimated m-value 8.0 s
|
0.000
|
|
Estimated Stiffness Modulus 15.0 s
|
0.000 MPa
|
|
Estimated m-value 15.0 s
|
0.000
|
|
Estimated Stiffness Modulus 30.0 s
|
0.000 MPa
|
|
Estimated m-value 30.0 s
|
0.000
|
|
Estimated Stiffness Modulus 60.0 s
|
97.691 MPa
|
|
Estimated m-value 60.0 s
|
0.327
|
|
Estimated Stiffness Modulus 120.0 s
|
0.000 MPa
|
|
Estimated m-value 120.0 s
|
0.000
|
|
Estimated Stiffness Modulus 240.0 s
|
0.000 MPa
|
|
Estimated m-value 240.0 s
|
0.000
|
DIME Test ID: 2026-08-11-92-9
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 09/18/2026
Date Tested: 09/16/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
PAV residue
|
|
Test Plate Diameter
|
8 mm
|
|
Phase Angle (δ) (for the 10 cycles)
|
44.1 degree
|
|
(G*) x sin(δ)=
|
3899 kPa
|