Print Report | Back to Sample Detail

Sample Record for 2026-08-29-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000781 DEA: 040P9304 EFIS: 0418000027 QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-80-7.6,12.8
Work Description: BRIDGE RAILING, MVP, CURB & GUTTER, SIDEWALKS, & ELECTRICAL SYSTEMS.
Location Description: CONTRA COSTA COUNTY IN PINOLE AT APPIAN WAY OVERCROSSING AND NEAR HERCULES AT CUMMINGS SKYWAY OVERCROSSING.
Contractor Name: BUGLER CONSTRUCTION, INC.
Contractor Address: 4847 Hopyard Road Ste 4-395, Pleasanton, CA 94588
Resident Engineer: Zhuohang Deng Structure Rep.: Rommoney Wu

Sample Information

DIME Sample ID: 2026-08-29-1
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3672 - Richmond
Sample Organization Contact: (510) 231-7108
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/29/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/29/2026
The quantity of what the sample constitutes: 32CY
A brief description of the sample: Concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Appian Way OC
The fabricator/manufacturer/facility name: Central

Material Information

The concrete mix design number: H45H1522
The truck number from where the sample was collected: 4
The batch plant ticket number from where the sample was collected: 02089102
Concrete batch plant: Martinez
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled: Approach slab
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-08-29-1-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/30/2026
Date Tested: 08/30/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: 6 hour break
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 8 lb
Average diameter of cylinder 1 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Compressive strength of cylinder (to nearest 10 psi) 190 psi
Maximum load on cylinder 1 2450 lb
Type of fracture pattern of cylinder 1 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen no data0 days
Age of specimen in hours 6 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-08-29-1-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/30/2026
Date Tested: 08/30/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: 7 hour break
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 1
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 9 lb
Average diameter of cylinder 1 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Compressive strength of cylinder (to nearest 10 psi) 480 psi
Maximum load on cylinder 1 5975 lb
Type of fracture pattern of cylinder 1 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen no data0 days
Age of specimen in hours 7 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-08-29-1-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/30/2026
Date Tested: 08/30/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: 12 hour breaks
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 9 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Compressive strength (to nearest 10 psi) 1990 psi
Maximum load on cylinder 1 21935 lb
Maximum load on cylinder 2 27975 lb
Compressive strength of cylinder 1 1750.0 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 2230.0 psi
Type of fracture pattern of cylinder 2 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen no data0 days
Age of specimen in hours 12 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-08-29-1-4
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/31/2026
Date Tested: 08/30/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: 24 hour break
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 9 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Compressive strength (to nearest 10 psi) 3370 psi
Maximum load on cylinder 1 38500 lb
Maximum load on cylinder 2 46150 lb
Compressive strength of cylinder 1 3060.0 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 3670.0 psi
Type of fracture pattern of cylinder 2 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 1 days
Age of specimen in hours no data
Serial number of delivery ticket, if available no data