Print Report | Back to Sample Detail

Sample Record for 2026-08-22-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000665 DEA: 081K4004 EFIS: 0819000031 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-3.5/6.8
Work Description: HMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC).
Location Description: TEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: 2900 Bristol Street, Suite D204, Costa Mesa, CA 92626
Resident Engineer: Denise Sostrom Structure Rep.: Gizachew Abayneh

Sample Information

DIME Sample ID: 2026-08-22-15
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/22/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/24/2026
The quantity of what the sample constitutes: 2 boxes of RHMA
A brief description of the sample: 1/2" RHMA-O-SP
From where was the sample collected: Manufacturer
Laboratory sample identification: 0543O-26
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble-Corona

Material Information

HMA Type: OGFC
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 51R003ARSPC
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2026-08-22-15-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/28/2026
Date Tested: 08/27/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2156.4 g
Corrected Asphalt Binder Content 7.25 %
Mass Loss 167.1 g
Correction Factor (Percent by mass of HMA Specimen) 0.36 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C