Print Report | Back to Sample Detail

Sample Record for 2026-06-18-96

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-06-18-96
TL Number from the TL Form:
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Asphalt Modifier
Sample Taken Date: 06/18/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/18/2026
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: CoC for Raffex 120 ACB
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tricor — San Joaquin Refining (Bakersfield, CA)

Material Information

Asphalt Modifier Type: Tricor/San Joaquin Refining
Asphalt Modifier Mix Number:

Test Results

Test

DIME Test ID: 2026-06-18-96-1
Test Method: ASTM D445-14: Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) (Kinematic Viscosity)
Verified Date: 08/28/2026
Date Tested: 06/18/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
First Kinematic Viscosity no data
Second Kinematic Viscosity no data
Kinematic Viscosity 24 m2/s
Dynamic Viscosity no data

Test

DIME Test ID: 2026-06-18-96-2
Test Method: ASTM D92-12b: Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester (Flash Point)
Verified Date: 08/28/2026
Date Tested: 06/18/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Ambient Barometric Pressure unit? mm Hg
Corrected Flash Point 227 C

Test

DIME Test ID: 2026-06-18-96-3
Test Method: ASTM D2007-11: Standard Test Method for Characteristic Groups in Rubber Extender and Processing Oils and Other Petroleum-Derived Oils by the Clay-Gel Absorption Chromatographic Method (Clay Gel Absorption)
Verified Date: 08/28/2026
Date Tested: 06/18/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Submitted from JMF - Ward Jenkins
Test Result Compliance:
Additional Comments When Verified:
Method of determination of aromatic content: Difference
Asphaltenes, percent by mass 0.0 %
Aromatics, percent by mass 65.0 %