Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000232 DEA: 09392304
QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-120,182-Var
Work Description: RECYCLE PAVEMENT, PLACE HMA, AND INSTALL GUARDRAIL.
Location Description: MONO COUNTY AT VARIOUS LOCATIONS
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2026-08-25-14
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/25/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/25/2026
The quantity of what the sample constitutes: HMA Sample 15
A brief description of the sample: 1/2 HMA SP R15
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction Lee Vining Plant
DIME Test ID: 2026-08-25-14-1
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/28/2026
Date Tested: 08/28/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-15
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7306.4 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1725 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8329.3 grams
|
|
Temperature of Water
|
77.3 °F
|
|
Specific Gravity for Sample 1
|
2.457
|
|
Theoretical maximum density at 25°C (77°F)
|
152.9 lb/ft^3
|
DIME Test ID: 2026-08-25-14-2
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/28/2026
Date Tested: 08/28/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-15
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4257.5 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5899.4 g
|
|
Corrected Asphalt Binder Content
|
5.05 %
|
|
Mass of HMA Sample prior to ignition
|
1641.9 g
|
|
Mass Loss
|
91.4 g
|
|
Mass of aggregate remaining after ignition
|
1550.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.52 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2026-08-25-14-3
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 08/28/2026
Date Tested: 08/26/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-15 PP Gradation
Test Result Compliance: complies
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
Yes
|
|
Aggregate correction factor for the 2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/4 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1/2 in. sieve (% passing)
|
-0.5 %
|
|
Aggregate correction factor for the 3/8 in. sieve (% passing)
|
-1.1 %
|
|
Aggregate correction factor for the #4 sieve (% passing)
|
-1.2 %
|
|
Aggregate correction factor for the #8 sieve (% passing)
|
-0.8 %
|
|
Aggregate correction factor for the #16 sieve (% passing)
|
-0.6 %
|
|
Aggregate correction factor for the #30 sieve (% passing)
|
-0.5 %
|
|
Aggregate correction factor for the #50 sieve (% passing)
|
-0.7 %
|
|
Aggregate correction factor for the #100 sieve (% passing)
|
-0.7 %
|
|
Aggregate correction factor for the #200 sieve (% passing)
|
-0.3 %
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
97 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
89 %
|
|
Cumulative percent passing the #4 sieve
|
60 %
|
|
Cumulative percent passing the #8 sieve
|
38 %
|
|
Cumulative percent passing the #16 sieve
|
26 %
|
|
Cumulative percent passing the #30 sieve
|
19 %
|
|
Cumulative percent passing the #50 sieve
|
13 %
|
|
Cumulative percent passing the #100 sieve
|
8 %
|
|
Cumulative percent passing the #200 sieve
|
4.8 %
|
DIME Test ID: 2026-08-25-14-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/28/2026
Date Tested: 08/26/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-15
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.387
|
|
Bulk Specific Gravity 2
|
2.391
|
|
Bulk Specific Gravity 3
|
2.386
|
|
Average Bulk Specific Gravity
|
2.388
|
DIME Test ID: 2026-08-25-14-5
Test Method: AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/28/2026
Date Tested: 08/26/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-15
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
2.8 %
|
|
Percent Air Voids 2
|
2.7 %
|
|
Percent Air Voids 3
|
2.8 %
|
|
Average Percent Air Voids
|
2.8 %
|
DIME Test ID: 2026-08-25-14-6
Test Method: AASHTO T166-16: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Saturated Surface-Dry Specimens (Method A)
Verified Date: 08/28/2026
Date Tested: 08/27/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-15
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
4
|
|
Bulk Specific Gravity 1
|
2.284
|
|
Bulk Specific Gravity 2
|
2.296
|
|
Bulk Specific Gravity 3
|
2.288
|
|
Bulk Specific Gravity 4
|
2.297
|
|
Percent of water absorbed by volume 1
|
0.66 %
|
|
Percent of water absorbed by volume 2
|
0.43 %
|
|
Percent of water absorbed by volume 3
|
0.53 %
|
|
Percent of water absorbed by volume 4
|
0.51 %
|
|
Average Bulk Specific Gravity
|
2.291
|
DIME Test ID: 2026-08-25-14-7
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 08/28/2026
Date Tested: 08/27/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-15
Test Result Compliance: complies
Additional Comments When Verified:
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A)
|
15000
|
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B)
|
15000
|
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A)
|
5.19 mm
|
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B)
|
11.5 mm
|
|
Stripping Inflection Point (Wheel A)
|
17845
|
|
Stripping Inflection Point (Wheel B)
|
12683
|