Print Report | Back to Sample Detail

Sample Record for 2026-08-21-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000232 DEA: 09392304 QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-120,182-Var
Work Description: RECYCLE PAVEMENT, PLACE HMA, AND INSTALL GUARDRAIL.
Location Description: MONO COUNTY AT VARIOUS LOCATIONS
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-08-21-11
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/21/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/21/2026
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: HMA Sample 12
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction Lee Vining Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2026-08-21-11-1
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/26/2026
Date Tested: 08/25/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-12
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7306.4 grams
Mass of oven-dry sample in air for Sample 1 1720.4 grams
Mass of container filled with the sample and water for Sample 1 8330.2 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.47
Theoretical maximum density at 25°C (77°F) 153.7 lb/ft^3

Test

DIME Test ID: 2026-08-21-11-2
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/26/2026
Date Tested: 08/25/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-12
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4283.4 g
Mass of the specimen and specimen basket assembly prior to ignition 5943.4 g
Corrected Asphalt Binder Content 5.19 %
Mass of HMA Sample prior to ignition 1660 g
Mass Loss 95.8 g
Mass of aggregate remaining after ignition 1564.2 g
Correction Factor (Percent by mass of HMA Specimen) 0.58 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test

DIME Test ID: 2026-08-21-11-3
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 08/26/2026
Date Tested: 08/25/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-12 PP Gradation
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/4 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1/2 in. sieve (% passing) -0.5 %
Aggregate correction factor for the 3/8 in. sieve (% passing) -1.1 %
Aggregate correction factor for the #4 sieve (% passing) -1.2 %
Aggregate correction factor for the #8 sieve (% passing) -0.8 %
Aggregate correction factor for the #16 sieve (% passing) -0.6 %
Aggregate correction factor for the #30 sieve (% passing) -0.5 %
Aggregate correction factor for the #50 sieve (% passing) -0.7 %
Aggregate correction factor for the #100 sieve (% passing) -0.7 %
Aggregate correction factor for the #200 sieve (% passing) -0.3 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 97 %
Cumulative percent passing the 3/8 in. sieve 88 %
Cumulative percent passing the #4 sieve 61 %
Cumulative percent passing the #8 sieve 39 %
Cumulative percent passing the #16 sieve 27 %
Cumulative percent passing the #30 sieve 19 %
Cumulative percent passing the #50 sieve 13 %
Cumulative percent passing the #100 sieve 8 %
Cumulative percent passing the #200 sieve 5.1 %