Print Report | Back to Sample Detail

Sample Record for 2026-06-15-102

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001609 DEA: 040AA244 EFIS: 0419000455 QA Service Level: 1
DIST-CO-RTE-PM: 04-CC, -680-R0.0/R7.7
Work Description: INDIVIDUAL SLAB REPLACEMENT, COLD PLAN AC PVMT, GRIND EXIST CONC PVMT.
Location Description: CONTRA COSTA COUNTY IN SAN RAMON AND DANVILLE FROM THE ALAMEDA COUNTY LINE TO 0.2 MILE NORTH OF DIABLO ROAD UNDERCROSSING
Contractor Name: Bay Cities Paving and Grading
Contractor Address: 1450 Civic Ct., Bldg B #400, Concord, CA 94520
Resident Engineer: Eddie Dike Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-06-15-102
TL Number from the TL Form: CPL061526
Sample Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Sample Organization Contact: (510) 507-3456
Type of Sample: Production Start-Up
Type of Material: Aggregate
Sample Taken Date: 06/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/07/2026
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4"HMA w/25% RAP
From where was the sample collected: Source
Laboratory sample identification: D04-SE-26-023
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Pleasanton Plant

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-01-0010
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant Sampler
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 220304

Test Results

Test

DIME Test ID: 2026-06-15-102-1
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Organization Address: 111 Grand Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94623
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 286-4717
Data has not been verified.

Test

DIME Test ID: 2026-06-15-102-2
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Organization Address: 111 Grand Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94623
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 286-4717
Data has not been verified.

Test

DIME Test ID: 2026-06-15-102-3
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Organization Address: 111 Grand Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94623
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 286-4717
Data has not been verified.

Test

DIME Test ID: 2026-06-15-102-4
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Organization Address: 111 Grand Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94623
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 286-4717
Data has not been verified.