Print Report | Back to Sample Detail

Sample Record for 2026-07-20-62

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001281 DEA: 11430234 EFIS: 1118000029 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-0.1/14.6
Work Description: REPLACE CONC PVMT, CONSTRUCT AUX LANE & BIKE TRAIL, ELECT, & LANDSCAPE
Location Description: SAN DIEGO COUNTY IN SAN DIEGO, CHULA VISTA AND NATIONAL CITY FROM 0.3 MILE SOUTH OF ROUTE 805/5 SEPARATION TO ROUTE 805/15 SEPARATION
Contractor Name: GRIFFITH COMPANY
Contractor Address: 13400 Sabre Springs, Suite 200 | San Diego, CA 92128, San Diego, CA 92128
Resident Engineer: Jason Alsheikh Structure Rep.: Carlos Guzman

Sample Information

DIME Sample ID: 2026-07-20-62
TL Number from the TL Form:
Sample Submitted By Organization: RMA Group - Rancho Cucamonga
Sample Organization Contact: (909) 989-1751
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 07/20/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/21/2026
The quantity of what the sample constitutes: 100cy
A brief description of the sample: Approach Slab
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Short Load Concrete

Material Information

The concrete mix design number: CTS-72-EHI
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Truck 15
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SB Rte805 at Naples St. Lane 2 Approach and Lane 1 Departure
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-07-20-62-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/19/2026
Date Tested: 07/21/2026
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test: Avg. Compressive Strength: 4900psi
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With density determined by dimension measurements
Average cylinder density (to nearest 1 pcf) 150 lb/ft^3
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data

Test

DIME Test ID: 2026-07-20-62-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/19/2026
Date Tested: 07/24/2026
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test: Avg. Compressive Strength: 6930psi
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With density determined by dimension measurements
Average cylinder density (to nearest 1 pcf) 150 lb/ft^3
Average diameter of cylinder 1 6.01 in
Average diameter of cylinder 2 6.01 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data

Test

DIME Test ID: 2026-07-20-62-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/19/2026
Date Tested: 08/18/2026
Submitted By Organization: RMA Group - Rancho Cucamonga
Organization Address: 12130 Santa Margarita Court,
Organization City: Rancho Cucamonga
Organization State: CA
Organization Zipcode: 91730
Organization Email: cbachler@rmacompanies.com
Organization Phone: (909) 989-1751
General Comments for this Test: Avg. Compressive Strength: 7460psi
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With density determined by dimension measurements
Average cylinder density (to nearest 1 pcf) 150 lb/ft^3
Average diameter of cylinder 1 6.01 in
Average diameter of cylinder 2 6.01 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data