Print Report | Back to Sample Detail

Sample Record for 2026-07-20-61

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000481 DEA: 081C07U4 EFIS: 0824000168 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-27.5/34.3
Work Description: RUBBERIZED HMA, FIBER OPTIC CABLE SYSTEMS, AND COLD PLANE AC PAVEMENT.
Location Description: RIVERSIDE COUNTY AT AND NEAR ROMOLAND AND HOMELAND FROM BONNIE DRIVE TO WINCHESTER ROAD
Contractor Name: GRIFFITH COMPANY
Contractor Address: 12200 Bloomfield Avenue, Santa Fe Springs, CA 90670
Resident Engineer: Omar Sanchez Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-07-20-61
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 07/20/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/24/2026
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Mariett(CCA) Lake Elsinore

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test

DIME Test ID: 2026-07-20-61-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 08/20/2026
Date Tested: 08/18/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 70 C
Softening Point Sample 2 70 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test

DIME Test ID: 2026-07-20-61-2
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 08/20/2026
Date Tested: 08/19/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 34 0.1 mm

Test

DIME Test ID: 2026-07-20-61-3
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 08/20/2026
Date Tested: 08/19/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 2 mm
Final Dial reading (F1) 60 mm
Ball Penetration (P2) 2 mm
Final Dial reading (F2) 60 mm
Ball Penetration (P3) 3 mm
Final Dial reading (F3) 60 mm
Resilience 1 42 %
Resilience 2 42 %
Resilience 3 43 %
Average Resilience 42 %
Minutes Reaction no data