Print Report | Back to Sample Detail

Sample Record for 2026-08-18-32

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001985 DEA: 010L9904 EFIS: 0122000073 QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-199-T0.6/0.8
Work Description: DN 199 Construct Roundabout
Location Description:
Contractor Name: S.T. Rhoades Construction
Contractor Address: 8780 Old Oregon Trail, Redding, CA 96001
Resident Engineer: Ryan Dunne Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-08-18-32
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - District 1 Materials Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Preliminary
Type of Material: Concrete
Sample Taken Date: 08/18/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/19/2026
The quantity of what the sample constitutes: Concrete Field Qualification
A brief description of the sample: PCC for CRPC
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tidewater Stary Pit

Material Information

The concrete mix design number: TWC-CT675PAV
The truck number from where the sample was collected: 121
The batch plant ticket number from where the sample was collected: 4115
Concrete batch plant: Tidewater Stary Pit
The fabricator/manufacturer designation for the sample: Qualification
A detailed description of where the material sample was collected: Concrete Chute
Where the material sample would have been placed if not sampled: N/A
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-08-18-32-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/21/2026
Date Tested: 08/21/2026
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 8/21/26 3 day Break
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 no data0 in^2
Cross sectional area of cylinder 2 no data0 in^2
Cross sectional area of cylinder 3 no data0 in^2
Compressive strength (to nearest 10 psi) no data0 psi
Maximum load on cylinder 1 20838 lb
Maximum load on cylinder 2 21373 lb
Maximum load on cylinder 3 22339 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 3 days
Age of specimen in hours no data0 hours

Test

DIME Test ID: 2026-08-18-32-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,RSP #1
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
This test has been superseded on 08/25/2026. The corrected test ID is: 2026-08-18-32-5
Reason: corrected

Test

DIME Test ID: 2026-08-18-32-4
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 08/20/2026
Date Tested: 08/18/2026
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Air Content 2 %

Test

DIME Test ID: 2026-08-18-32-5
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/25/2026
Date Tested: 08/24/2026
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 8/24/26 6 Day Break
The test was superseded from test ID: 2026-08-18-32-2
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 2400 psi
Maximum load on cylinder 1 30305 lb
Maximum load on cylinder 2 29579 lb
Maximum load on cylinder 3 30624 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 6 days
Age of specimen in hours no data0 hours