Sample Record for 2026-08-17-48
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001194 DEA: 051H4404 EFIS: 0516000074
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB,SLO-1-50.3/50.6,0.0/0.3
Work Description: SANTA MARIA RIVER BRIDGE (REPLACE).
Location Description: SANTA BARBARA AND SAN LUIS OBISPO COUNTIES IN AND NEAR GUADALUPE AT SANTA MARIA RIVER BRIDGE
Contractor Name: M.C.M. CONSTRUCTION, INC.
Contractor Address: 6413 32nd Street, North Highlands, Ca 95660
Resident Engineer: Jacob Cooper Structure Rep.: Sal Heredia
Sample Information
DIME Sample ID: 2026-08-17-48
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 08/17/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/19/2026
The quantity of what the sample constitutes: 48
A brief description of the sample: HRC 500-510 coupler
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor HRC
Material Information
Production or Authorization Testing: Authorization Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Nucor
Coupler Manufacturer: HRC Nucor
Intermediate Assembler or Fabricator:
Rebar Size: #10
Coupler Model: HRC 500/510
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): 74141308 74143700
Rebar Heat Number(s): 3500041544
Rebar Size 2 :
Coupler Unique ID: TPT-17-04
Test Results
Test
DIME Test ID: 2026-08-17-48-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 09/01/2026
Date Tested: 09/01/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
4
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 1 | 1 | 10 | 1.27 | 0.005 | 117910 | 93000 | ok necking | Kleinfelder | | 2 | 1 | 10 | 1.27 | 0000 | 116700 | 92000 | ok necking | Kleinfelder | | 3 | 1 | 10 | 1.27 | 0000 | 117000 | 92000 | ok necking | Kleinfelder | | 4 | 1 | 10 | 1.27 | 0000 | 119550 | 94000 | ok necking | Kleinfelder |
| |
|
Temperature
|
0 f
|
|
UTM
|
NA
|
|
Halo ID
|
na
|