Sample Record for 2025-12-15-62
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001375 DEA: 040A53T4 EFIS: 0421000155 COOP: 040A53TCM
QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-80-L1.8/L3.2
Work Description: Construct I-80 WB Truck Scales
Location Description: CONSTRUCTION ON STATE HIGHWAY IN SOLANO COUNTY IN AND NEAR FAIRFIELD ON ROUTE 12 FROM THE 80/12 EAST JUNCTION TO 0.9 MILE EAST OF CHADBOURNE ROAD UNDERCROSSING AND ON ROUTE 80 FROM 0.5 MILE WEST OF DAN WILSON CREEK BRIDGE TO WEST TEXAS STREET UNDERCROSSI
Contractor Name: Kiewit Infrastructure West Co.
Contractor Address: 4650 Business Center Drive, Fairfield, CA 94534
Resident Engineer: Darren Isada Structure Rep.: Nana Budu
Sample Information
DIME Sample ID: 2025-12-15-62
TL Number from the TL Form:
Sample Submitted By Organization: G3 Quality, Incorporated - Cerritos
Sample Organization Contact: (562) 321-9840
Type of Sample: Per Request
Type of Material: Concrete
Sample Taken Date: 12/15/2025
Date that the sample was received by the laboratory/organization performing the testing: 12/16/2025
The quantity of what the sample constitutes: 2
A brief description of the sample: 4x8 cylinders
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex Fairfield
Material Information
The concrete mix design number: 1635786
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 0
Concrete batch plant: Cemex Fairfield
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Batch Plant
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test
DIME Test ID: 2025-12-15-62-1
Test Method: AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete
Verified Date: 08/17/2026
Date Tested: 01/12/2026
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Average CTE
|
0.000009862 mm/mm/°C
|
|
Average CTE
|
5.479E-6 in/in/°F
|
Test
DIME Test ID: 2025-12-15-62-2
Test Method: AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete
Verified Date: 08/17/2026
Date Tested: 01/12/2026
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Average CTE
|
0.000010201 mm/mm/°C
|
|
Average CTE
|
5.667E-6 in/in/°F
|