Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 99999 DEA: 0322222
QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown
DIME Sample ID: 2026-08-17-4
TL Number from the TL Form:
Sample Submitted By Organization: Stonemont Solutions, Incorporated
Sample Organization Contact: (970) 674-1148
Type of Sample: Quality Control
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/17/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/17/2026
The quantity of what the sample constitutes: 1532
A brief description of the sample: TRUCK
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Windsor Asphalt
HMA Type: Type A HMA
HMA Grading: 1 inch
Lot number: 1
Sublot number: 2
HMA Mix Number: 2541
Binder content (%): 5.4
Virgin binder PG: PG 64-10
Design binder PG: PG 58-16
Binder Supplier: Windsor Binder
RAP content (%): 25
WMA Additives: Yes
Antistrip type: Hyrodset
DIME Test ID: 2026-08-17-4-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/17/2026
Date Tested: 08/17/2026
Submitted By Organization: Stonemont Solutions, Incorporated
Organization Address: 128 North 6th Street, Suite A,
Organization City: Windsor
Organization State: CO
Organization Zipcode: 80550
Organization Email: jbeal@stonemont.com
Organization Phone: (970) 674-1148
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Corrected Asphalt Binder Content
|
4.52 %
|
|
Mass of HMA Sample prior to ignition
|
1542.4 g
|
|
Mass Loss
|
150.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.25 %
|
|
Moisture Content
|
0.15 %
|
|
Temperature Compensation Factor
|
0.24 %
|
|
Test Temperature
|
300 F
|