Print Report | Back to Sample Detail

Sample Record for 2026-08-01-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000607 DEA: 081K6904 EFIS: 0819000090 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-5.7/11.8
Work Description: ROCK EXCAVATION, HMA (TYPE A), RHMA-G, AND CABLE NET DRAPERY SYSTEM.
Location Description: RIVERSIDE COUNTY IN AND NEAR LAKE ELSINORE FROM MONTE VISTA STREET TO GRAND AVENUE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: Fereydoon Alipanah Structure Rep.: Gizachew Abayneh

Sample Information

DIME Sample ID: 2026-08-01-11
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/01/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/03/2026
The quantity of what the sample constitutes: 2 Boxes of HMA-A
A brief description of the sample: 3/4" HMA-A
From where was the sample collected: Manufacturer
Laboratory sample identification: 0478A-26
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta (CCA) Lake Elsinore

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 53417105
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2026-08-01-11-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/14/2026
Date Tested: 08/06/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2259.6 g
Corrected Asphalt Binder Content 4.92 %
Mass Loss 130.6 g
Correction Factor (Percent by mass of HMA Specimen) 0.72 %
Moisture Content no data0 %
Temperature Compensation Factor 0.13 %
Test Temperature 538 C