Print Report | Back to Sample Detail

Sample Record for 2026-08-11-51

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994418 DEA: 040J5504 EFIS: 0414000012 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-84-17.2/17.2
Work Description: REPLACE BRIDGE, WIDEN ROADWAY, & CONSTRUCT SIDEWALKS.
Location Description: ALAMEDA COUNTY AT SUNOL FROM SILVER SPRING ROAD UNDERPASS TO PLEASANTON SUNOL ROAD
Contractor Name: GHILOTTI CONSTRUCTION CO. INC.
Contractor Address: 246 GHILOTTI AVE., SANTA ROSA, CA 95407
Resident Engineer: Scott Sowko Structure Rep.: Jordan Jarosz

Sample Information

DIME Sample ID: 2026-08-11-51
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3674 - Livermore
Sample Organization Contact: (510) 393-1493
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/11/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/26/2026
The quantity of what the sample constitutes: 27 CY
A brief description of the sample: structural concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 33-0774
Structure name: Arroyo De La Laguna
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: 1636582
The truck number from where the sample was collected: 76147
The batch plant ticket number from where the sample was collected: 4431A
Concrete batch plant: CEMEX
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-08-11-51-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/08/2026
Date Tested: 09/08/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 6250 psi
Maximum load on cylinder 1 80380 lb
Maximum load on cylinder 2 76670 lb
Maximum load on cylinder 3 78625 lb
Compressive strength of cylinder 1 6394.6 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 6099.4 psi
Compressive strength of cylinder 3 6255 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours