Print Report | Back to Sample Detail

Sample Record for 2026-07-15-89

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993331 DEA: 023H6904 EFIS: 0218000010 QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-89-30/R42.1
Work Description: ALMANOR WEST REHAB - ROADWAY REHABILITATION
Location Description: IN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36.
Contractor Name: DIG IT CONSTRUCTION, INC.
Contractor Address: Unknown
Resident Engineer: Sergio Mendoza Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-07-15-89
TL Number from the TL Form: 848646
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/15/2026
The quantity of what the sample constitutes: Production Start Up Evaluation
A brief description of the sample: 16 Boxes of Lime treated 3/4-inch Type A HMA (eq.64.28)
From where was the sample collected: Manufacturer
Laboratory sample identification: D80293
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dig It Construction - Sierra Cascade Aggregate and Asphalt Products - Chester, CA

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%): 5.9
Virgin binder PG:
Design binder PG: PG 64-28
Binder Supplier: Albina (Klamath Falls, OR)
RAP content (%): 24
WMA Additives: No
Antistrip type: 1% Lime

Test Results

Test

DIME Test ID: 2026-07-15-89-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/12/2026
Date Tested: 08/12/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.433
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7330.6 grams
Mass of oven-dry sample in air for Sample 1 2650.1 grams
Mass of container filled with the sample and water for Sample 1 8891.3 grams
Temperature of Water 76 °F
Specific Gravity for Sample 1 2.433
Theoretical maximum density at 25°C (77°F) 2425.9 kg/m^3

Test

DIME Test ID: 2026-07-15-89-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/12/2026
Date Tested: 07/28/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=5.07%, Target=5.65%
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3019.8 g
Mass of the specimen and specimen basket assembly prior to ignition 5133.9 g
Mass of HMA Sample prior to ignition 2114.1 g
Corrected Asphalt Binder Content 5.07 %
Mass Loss 122.2 g
Mass of aggregate remaining after ignition 1991.9 g
Correction Factor (Percent by mass of HMA Specimen) 0.58 %
Moisture Content no data0 %
Temperature Compensation Factor 0.13 %
Test Temperature 538 C

Test

DIME Test ID: 2026-07-15-89-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/12/2026
Date Tested: 07/21/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmb=2.375
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.384
Bulk Specific Gravity 2 2.368
Bulk Specific Gravity 3 2.373
Average Bulk Specific Gravity 2.375

Test

DIME Test ID: 2026-07-15-89-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/12/2026
Date Tested: 08/12/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: AASHTO T 269: Pa=2.4% Allowed tolerance for air voids is 2.5 – 5.5%
Test Result Compliance: does not comply
Additional Comments When Verified:
Percent Air Voids 2 %
Percent Air Voids 2 2.7 %
Percent Air Voids 3 2.5 %
Average Percent Air Voids 2.4 %

Test

DIME Test ID: 2026-07-15-89-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 08/12/2026
Date Tested: 08/07/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: S₁=172 psi, S₂=168 psi, TSR=98%
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 172 psi
Average Wet Tensile Strength 168 psi
Tensile Strength Ratio 0.98