Print Report | Back to Sample Detail

Sample Record for 2026-08-12-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001375 DEA: 040A53T4 EFIS: 0421000155 COOP: 040A53TCM QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-80-L1.8/L3.2
Work Description: Construct I-80 WB Truck Scales
Location Description: CONSTRUCTION ON STATE HIGHWAY IN SOLANO COUNTY IN AND NEAR FAIRFIELD ON ROUTE 12 FROM THE 80/12 EAST JUNCTION TO 0.9 MILE EAST OF CHADBOURNE ROAD UNDERCROSSING AND ON ROUTE 80 FROM 0.5 MILE WEST OF DAN WILSON CREEK BRIDGE TO WEST TEXAS STREET UNDERCROSSI
Contractor Name: Kiewit Infrastructure West Co.
Contractor Address: 4650 Business Center Drive, Fairfield, CA 94534
Resident Engineer: Darren Isada Structure Rep.: Nana Budu

Sample Information

DIME Sample ID: 2026-08-12-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/12/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/13/2026
The quantity of what the sample constitutes: 50
A brief description of the sample: Hvy Hex Bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KW Indistires

Material Information

Rocap Number(s): n/a
Heat Number(s): 10791550
Nut Mfg. Lot Number(s): n/a
Washer Mfg. Lot Number(s): n/a
Bolt Specification: A325
Bolt Length(s): 2-1/2"
Nut Specification: n/a
Washer Specification: n/a
Finish: HDG/blue dye
Diameter/Size: 3/4"-10
Bolt Mfg. Lot Number: E210I1
Rocap Test Requirement(s): no
Lubricant Requirements(s): yes
Washer Inner Diameter(s): no

Test Results

Test

DIME Test ID: 2026-08-12-2-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/25/2026
Date Tested: 08/13/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 10791550
Mfg. Lot Number E20911
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 USA LE
Size 0.75 in
Bolt Length 2.5 in
Pitch Diameter 0.6870 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-08-12-2-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/25/2026
Date Tested: 08/24/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E21011
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size no data in
Bolt Length no data in
Measurement Average 4.4 mils

Test

DIME Test ID: 2026-08-12-2-3
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/25/2026
Date Tested: 08/24/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1AE209110.754814000TensileWSP
UTM NA
Temperature 0 f