Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030F3104 Cty ED Rte 49 PM 23.6/24.5 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Jeff Hamm |
Date Reported: |
06/06/2018 |
|
Address: |
TL Number: |
154480 |
||
City: |
||||
Project Name: REPLACE BRIDGE. |
||||
Prime Contractor: M.C.M. CONSTRUCTION, INC. |
||||
Sample Taken Date: |
04/25/2018 |
Mix Design: |
sr850cfst0 |
|
Contractor: Unknown |
Location : EL DORADO COUNTY NEAR COLOMA FROM 0.1 MILE EAST OF MARSHALL ROAD TO 0.3 MILE EAST OF LOTUS ROAD |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 179606 | 6330.8 | 1 |
2 | 6.02 | 28.46 | 179927 | 6322.1 | 1 |
DIME Test ID: 2018-04-25-7-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6330
Age of specimen: 42 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing