Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001669 DEA: 09379004 EFIS: 0919000004
QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-R65.0/76.0
Work Description: FULL DEPTH RECYCLING, COLD PLANE, HMA AND CURB RAMPS.
Location Description: INYO COUNTY AT AND NEAR INDEPENDENCE FROM 3 MILES SOUTH OF MANZANAR REWARD ROAD TO 0.3 MILE NORTH OF SHABBELL LANE
Contractor Name: ROAD AND HIGHWAY BUILDERS LLC
Contractor Address: 950 E MUSTANG RD, SPARKS NV 89434
Resident Engineer: Garrett Rottner Structure Rep.: Unknown
DIME Sample ID: 2026-08-03-5
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/03/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/03/2026
The quantity of what the sample constitutes: 16 boxes of 3/4" Type A HMA with RAP
A brief description of the sample: 0 - 750 tons for today
From where was the sample collected: Job Site
Laboratory sample identification: HMA - 86
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Grinding Rock - Independence
DIME Test ID: 2026-08-03-5-1
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/06/2026
Date Tested: 08/04/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-86
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7306.4 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2173.9 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8609 grams
|
|
Temperature of Water
|
77.3 °F
|
|
Specific Gravity for Sample 1
|
2.495
|
|
Theoretical maximum density at 25°C (77°F)
|
155.3 lb/ft^3
|
DIME Test ID: 2026-08-03-5-2
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/06/2026
Date Tested: 08/04/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-86
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4282.1 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6395.8 g
|
|
Corrected Asphalt Binder Content
|
4.73 %
|
|
Mass of HMA Sample prior to ignition
|
2113.7 g
|
|
Mass Loss
|
113.6 g
|
|
Mass of aggregate remaining after ignition
|
2000.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.64 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2026-08-03-5-3
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 08/06/2026
Date Tested: 08/04/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-86 PP Gradation
Test Result Compliance: complies
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
Yes
|
|
Aggregate correction factor for the 2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/4 in. sieve (% passing)
|
-1 %
|
|
Aggregate correction factor for the 1/2 in. sieve (% passing)
|
-0.2 %
|
|
Aggregate correction factor for the 3/8 in. sieve (% passing)
|
-0.3 %
|
|
Aggregate correction factor for the #4 sieve (% passing)
|
-1.1 %
|
|
Aggregate correction factor for the #8 sieve (% passing)
|
-1.2 %
|
|
Aggregate correction factor for the #16 sieve (% passing)
|
-0.9 %
|
|
Aggregate correction factor for the #30 sieve (% passing)
|
-0.7 %
|
|
Aggregate correction factor for the #50 sieve (% passing)
|
-0.5 %
|
|
Aggregate correction factor for the #100 sieve (% passing)
|
-0.2 %
|
|
Aggregate correction factor for the #200 sieve (% passing)
|
-0.1 %
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
96 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
84 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
77 %
|
|
Cumulative percent passing the #4 sieve
|
49 %
|
|
Cumulative percent passing the #8 sieve
|
36 %
|
|
Cumulative percent passing the #16 sieve
|
26 %
|
|
Cumulative percent passing the #30 sieve
|
18 %
|
|
Cumulative percent passing the #50 sieve
|
11 %
|
|
Cumulative percent passing the #100 sieve
|
8 %
|
|
Cumulative percent passing the #200 sieve
|
4.9 %
|
DIME Test ID: 2026-08-03-5-4
Test Method: AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-86
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
3.8 %
|
|
Percent Air Voids 2
|
3.9 %
|
|
Percent Air Voids 3
|
3.8 %
|
|
Average Percent Air Voids
|
3.8 %
|
DIME Test ID: 2026-08-03-5-5
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/06/2026
Date Tested: 08/04/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-86
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.399
|
|
Bulk Specific Gravity 2
|
2.398
|
|
Bulk Specific Gravity 3
|
2.4
|
|
Average Bulk Specific Gravity
|
2.399
|
DIME Test ID: 2026-08-03-5-6
Test Method: AASHTO T166-25: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Saturated Surface-Dry Specimens (Method A)
Verified Date: 08/06/2026
Date Tested: 08/05/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-86
Test Result Compliance:
Additional Comments When Verified:
|
Number of tests
|
4
|
|
Bulk Specific Gravity 1
|
2.317
|
|
Bulk Specific Gravity 2
|
2.317
|
|
Bulk Specific Gravity 3
|
2.322
|
|
Bulk Specific Gravity 4
|
2.323
|
|
Percent of water absorbed by volume 1
|
1.36 %
|
|
Percent of water absorbed by volume 2
|
1.38 %
|
|
Percent of water absorbed by volume 3
|
1.25 %
|
|
Percent of water absorbed by volume 4
|
0.97 %
|
|
Average Bulk Specific Gravity
|
2.32
|
DIME Test ID: 2026-08-03-5-7
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 08/06/2026
Date Tested: 08/05/2026
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-86
Test Result Compliance: complies
Additional Comments When Verified:
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A)
|
15000
|
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B)
|
15000
|
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A)
|
2.58 mm
|
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B)
|
3.16 mm
|
|
Stripping Inflection Point (Wheel A)
|
0
|
|
Stripping Inflection Point (Wheel B)
|
0
|