Print Report | Back to Sample Detail

Sample Record for 2026-07-29-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000607 DEA: 081K6904 EFIS: 0819000090 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-5.7/11.8
Work Description: ROCK EXCAVATION, HMA (TYPE A), RHMA-G, AND CABLE NET DRAPERY SYSTEM.
Location Description: RIVERSIDE COUNTY IN AND NEAR LAKE ELSINORE FROM MONTE VISTA STREET TO GRAND AVENUE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: Fereydoon Alipanah Structure Rep.: Gizachew Abayneh

Sample Information

DIME Sample ID: 2026-07-29-31
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/29/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2026
The quantity of what the sample constitutes: 9
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Robertson's

Material Information

The concrete mix design number: SC590B33
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Job site
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-07-29-31-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/26/2026
Date Tested: 08/26/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 3.99 in
Average diameter of cylinder 2 3.99 in
Average diameter of cylinder 3 3.99 in
Cross sectional area of cylinder 1 12.5 in^2
Cross sectional area of cylinder 2 12.5 in^2
Cross sectional area of cylinder 3 12.5 in^2
Compressive strength (to nearest 10 psi) 4480 psi
Maximum load on cylinder 1 57090 lb
Maximum load on cylinder 2 54280 lb
Maximum load on cylinder 3 56690 lb
Compressive strength of cylinder 1 4570.0 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 4340.0 psi
Compressive strength of cylinder 3 4540 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-07-29-31-4
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/06/2026
Date Tested: 08/05/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3090 psi
Maximum load on cylinder 1 40570 lb
Maximum load on cylinder 2 37400 lb
Maximum load on cylinder 3 38650 lb
Compressive strength of cylinder 1 3230.0 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 2980.0 psi
Compressive strength of cylinder 3 3070 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-07-29-31-5
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/12/2026
Date Tested: 08/12/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3730 psi
Maximum load on cylinder 1 49290 lb
Maximum load on cylinder 2 45150 lb
Maximum load on cylinder 3 46680 lb
Compressive strength of cylinder 1 3900.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 3590.0 psi
Compressive strength of cylinder 3 3710 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-07-29-31-6
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/27/2026
Date Tested: 08/26/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (213) 792-4797
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 3.99 in
Average diameter of cylinder 2 3.99 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.5 in^2
Cross sectional area of cylinder 2 12.5 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4470 psi
Maximum load on cylinder 1 57090 lb
Maximum load on cylinder 2 54280 lb
Maximum load on cylinder 3 56690 lb
Compressive strength of cylinder 1 4570.0 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 4340.0 psi
Compressive strength of cylinder 3 4510 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data