Print Report | Back to Sample Detail

Sample Record for 2026-07-31-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001281 DEA: 11430234 EFIS: 1118000029 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-0.1/14.6
Work Description: REPLACE CONC PVMT, CONSTRUCT AUX LANE & BIKE TRAIL, ELECT, & LANDSCAPE
Location Description: SAN DIEGO COUNTY IN SAN DIEGO, CHULA VISTA AND NATIONAL CITY FROM 0.3 MILE SOUTH OF ROUTE 805/5 SEPARATION TO ROUTE 805/15 SEPARATION
Contractor Name: GRIFFITH COMPANY
Contractor Address: 13400 Sabre Springs, Suite 200 | San Diego, CA 92128, San Diego, CA 92128
Resident Engineer: Jason Alsheikh Structure Rep.: Carlos Guzman

Sample Information

DIME Sample ID: 2026-07-31-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 07/31/2026
Date that the sample was received by the laboratory/organization performing the testing: 08/11/2026
The quantity of what the sample constitutes: 11 pcs
A brief description of the sample: #9 Gr 75 (ASTM A615) All Thread Bar and Hex Nuts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Engineering

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type:
Rebar Size:
Nut Specification for Threaded Bar: ASTM A29/A108
System Manufacturer: Williams Form Engineering San Diego
Epoxy Coating Color: NA
Threaded Bar Application:
Coating Standards: Uncoated
Bar Heat Number(s): 1000235791
Nut Heat Number(s): 1000128766
Bar Lot Number:
Nut Lot Number:
Coupler Heat Number(s):
Coupler Grade:

Test Results

Test

DIME Test ID: 2026-07-31-2-1
Test Method: ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 08/18/2026
Date Tested: 08/18/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 2
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
1910002357911108000838900000A615 Bar and NutKleinfelder
2910002357911126000988109A615 BarKleinfelder
Temperature 0 f
UTM NA