Project Information
Project ID: 993118 DEA: 101C3304 EFIS: 1014000146
QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-205-R4.6/R9.0
Work Description: Widening bridges, ramps and roadway. SR205 SMART CORRIDOR - PHASE 2
Location Description: On state highway in San Joaquin County in and near Tracy from Janney Overhead to 1.3 miles east of MacArthur Drive Overcrossing.
Contractor Name: Bay Cities Paving & Grading Inc.
Contractor Address: 1450 Civic Ct., Bldg B #400, Concord, CA 94520
Resident Engineer: Harminder Deol Structure Rep.: Ron Matin
Sample Information
DIME Sample ID: 2026-07-29-29
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 07/29/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2026
The quantity of what the sample constitutes: 4
A brief description of the sample: #11 Coupler
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: C&N Reinforcment
Material Information
Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: CMC
Coupler Manufacturer: HRC
Intermediate Assembler or Fabricator:
Rebar Size: #11
Coupler Model: HRC 500/510
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): 73142156, 73142654
Rebar Heat Number(s): 9012799, 9012800
Rebar Size 2 :
Coupler Unique ID: TP-17-03
Test Results
Test
DIME Test ID: 2026-07-29-29-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 08/10/2026
Date Tested: 08/10/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
4
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 1 | 1 | 11 | 1.56 | 0.0021 | 146670 | 94019 | NA | Atlas | | 2 | 1 | 11 | 1.56 | 0 | 147500 | 94551 | NA | Atlas | | 3 | 1 | 11 | 1.56 | 0 | 147830 | 94763 | NA | Atlas | | 4 | 1 | 11 | 1.56 | 0 | 147070 | 94276 | NA | Atlas |
| |
|
Temperature
|
0 f
|
|
UTM
|
NA
|
|
Halo ID
|