Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1002460 DEA: 113A9424 EFIS: 1125000157
QA Service Level: 1
DIST-CO-RTE-PM: 11---unknown
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2026-07-15-73
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/16/2026
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: Plant Sample
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: MM Lakeside
DIME Test ID: 2026-07-15-73-1
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 09/01/2026
Date Tested: 07/30/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Cores
|
1
|
|
Core ID
|
1A1
|
|
Dry Weight
|
1080.8 grams
|
|
Parrafin Coated Weight
|
1096.2 grams
|
|
Coated Weight in Water
|
613 grams
|
|
Theoretical Maximum Density
|
2.45
|
DIME Test ID: 2026-07-15-73-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/01/2026
Date Tested: 09/04/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Does NOT comply, tested 6.63%, min required is 7.1%
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4045.9 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6091.8 g
|
|
Mass of HMA Sample prior to ignition
|
2045.9 g
|
|
Corrected Asphalt Binder Content
|
6.63 %
|
|
Mass Loss
|
150.8 g
|
|
Mass of aggregate remaining after ignition
|
1895.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.74 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2026-07-15-73-3
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/01/2026
Date Tested: 09/04/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7477.8 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2547.1 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8985.4 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.45
|
|
Theoretical maximum density at 25°C (77°F)
|
152.5 lb/ft^3
|
DIME Test ID: 2026-07-15-73-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/08/2026
Date Tested: 09/04/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: N/A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.342
|
|
Bulk Specific Gravity 2
|
2.33
|
|
Bulk Specific Gravity 3
|
2.327
|
|
Average Bulk Specific Gravity
|
2.333
|
DIME Test ID: 2026-07-15-73-5
Test Method: AASHTO T269-24E25: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/08/2026
Date Tested: 09/04/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
4.4 %
|
|
Percent Air Voids 2
|
4.9 %
|
|
Percent Air Voids 3
|
5 %
|
|
Average Percent Air Voids
|
4.8 %
|
DIME Test ID: 2026-07-15-73-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
Data has not been verified.
DIME Test ID: 2026-07-15-73-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/10/2026
Date Tested: 09/09/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Retest did NOT COMPLY - Target 7.50 % - Re-tested 6.73%
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4036.7 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6090.6 g
|
|
Mass of HMA Sample prior to ignition
|
2053.9 g
|
|
Corrected Asphalt Binder Content
|
6.73 %
|
|
Mass Loss
|
153.4 g
|
|
Mass of aggregate remaining after ignition
|
1900.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.74 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2026-07-15-73-8
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
Data has not been verified.