Print Report | Back to Sample Detail

Sample Record for 2026-07-27-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001941 DEA: 040V5104 EFIS: 0426000263 COOP: NONE QA Service Level: 1
DIST-CO-RTE-PM: 04-SON--unknown
Work Description:
Location Description:
Contractor Name: Pacific Coast Drilling Co., Inc.
Contractor Address: 364 Bellevue Ave., Santa Rosa 95407
Resident Engineer: Leonard Brajnikoff Structure Rep.: nick Abuhamdieh

Sample Information

DIME Sample ID: 2026-07-27-31
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3672 - Santa Rosa
Sample Organization Contact: (510) 774-6009
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/27/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/28/2026
The quantity of what the sample constitutes: 11CY
A brief description of the sample: CONCRETE WALER
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Ecoterra Ready Mix

Material Information

The concrete mix design number: 7SK5K1X425F
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 515
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: concrete sample from wheel barrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-07-27-31-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/03/2026
Date Tested: 08/03/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: A LOT of surface air void holes around the outside of the cylinders
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Compressive strength (to nearest 10 psi) 5990 psi
Maximum load on cylinder 1 77595 lb
Maximum load on cylinder 2 73090 lb
Compressive strength of cylinder 1 6173.0 psi
Type of fracture pattern of cylinder 1 6
Compressive strength of cylinder 2 5814.6 psi
Type of fracture pattern of cylinder 2 6
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data

Test

DIME Test ID: 2026-07-27-31-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/10/2026
Date Tested: 08/10/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Compressive strength (to nearest 10 psi) 6850 psi
Maximum load on cylinder 1 84280 lb
Maximum load on cylinder 2 87990 lb
Compressive strength of cylinder 1 6704.9 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 7000.0 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 14 days
Age of specimen in hours no data0 hours

Test

DIME Test ID: 2026-07-27-31-3
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/24/2026
Date Tested: 08/24/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Compressive strength (to nearest 10 psi) 6650 psi
Maximum load on cylinder 1 83080 lb
Maximum load on cylinder 2 84000 lb
Compressive strength of cylinder 1 6609.4 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 6682.6 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours no data