Sample Record for 2026-07-27-28
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001075 DEA: 040W0304 EFIS: 0420000164
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-580-0.02/6.3
Work Description: Replace existing tolling structure with open road tolling (ORT) system at the Richmond-San Rafael.
Location Description:
Contractor Name: FLATIRON WEST INC.
Contractor Address: 1200 Concord Ave Suite 465, Concord, CA 94520
Resident Engineer: William Sommer Structure Rep.: Eric Racadag
Sample Information
DIME Sample ID: 2026-07-27-28
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/27/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2026
The quantity of what the sample constitutes: 800
A brief description of the sample: 5/8 x 2 A325
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: XKT Engineering
Material Information
Rocap Number(s): E973J1R
Heat Number(s): 10821880 1000230730 A82280
Nut Mfg. Lot Number(s): W000328595
Washer Mfg. Lot Number(s): E8078
Bolt Specification: ASTM A325
Bolt Length(s): 2
Nut Specification: ASTM A563
Washer Specification: ASTM F436
Finish: HDG
Diameter/Size: 5/8 x 2
Bolt Mfg. Lot Number: E973J1
Rocap Test Requirement(s): E973J1R
Lubricant Requirements(s): wax
Washer Inner Diameter(s): 000
Test Results
Test
DIME Test ID: 2026-07-27-28-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/18/2026
Date Tested: 08/03/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
E971J1
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
A325 LA USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
2 in
|
|
Pitch Diameter
|
0.5720 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test
DIME Test ID: 2026-07-27-28-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/18/2026
Date Tested: 08/03/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
E971J1
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
A325 LA USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
2 in
|
|
Pitch Diameter
|
0.5720 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test
DIME Test ID: 2026-07-27-28-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/18/2026
Date Tested: 08/03/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
E971J1
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
A325 LA USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
2 in
|
|
Pitch Diameter
|
0.5720 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test
DIME Test ID: 2026-07-27-28-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E971J1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.7 mils
|
Test
DIME Test ID: 2026-07-27-28-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E971J1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.3 mils
|
Test
DIME Test ID: 2026-07-27-28-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E971J1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.2 mils
|
Test
DIME Test ID: 2026-07-27-28-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
W000328595
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.8 mils
|
Test
DIME Test ID: 2026-07-27-28-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
W000328595
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.8 mils
|
Test
DIME Test ID: 2026-07-27-28-9
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
W000328595
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.3 mils
|
Test
DIME Test ID: 2026-07-27-28-10
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E8078
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.6 mils
|
Test
DIME Test ID: 2026-07-27-28-11
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E8078
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
4.6 mils
|
Test
DIME Test ID: 2026-07-27-28-12
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E8078
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
5.8 mils
|
Test
DIME Test ID: 2026-07-27-28-13
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E8078
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
37
|
|
Spacing
|
Ok
|
Test
DIME Test ID: 2026-07-27-28-14
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E8078
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
39
|
|
Spacing
|
Ok
|
Test
DIME Test ID: 2026-07-27-28-15
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E8078
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.625 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
40
|
|
Spacing
|
Ok
|
Test
DIME Test ID: 2026-07-27-28-16
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
2
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | E971J1 | 0.625 | 31055 | 0 | 0 | Tensile | WSP | | 1B | E971J1 | 0.625 | 30660 | 0 | 0 | Tensile | WSP |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|
Test
DIME Test ID: 2026-07-27-28-17
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/18/2026
Date Tested: 08/12/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
2
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | W000328595 | 0.625 | 39550 | 0 | 0 | Nut Proof Load | WSP | | 1B | W000328595 | 0.625 | 39550 | 0 | 0 | Nut Proof Load | WSP |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|