Project ID: 1001194 DEA: 051H4404 EFIS: 0516000074
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB,SLO-1-50.3/50.6,0.0/0.3
Work Description: SANTA MARIA RIVER BRIDGE (REPLACE).
Location Description: SANTA BARBARA AND SAN LUIS OBISPO COUNTIES IN AND NEAR GUADALUPE AT SANTA MARIA RIVER BRIDGE
Contractor Name: M.C.M. CONSTRUCTION, INC.
Contractor Address: 6413 32nd Street, North Highlands, Ca 95660
Resident Engineer: Jacob Cooper Structure Rep.: Sal Heredia
DIME Sample ID: 2026-07-27-27
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Quality Assurance
Type of Material: Precast Concrete
Sample Taken Date: 07/27/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/28/2026
The quantity of what the sample constitutes: 83 cy
A brief description of the sample: set of three 4x8 cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pinnacle Prestress, Inc.
The concrete mix design number: CON-NFA-9.00-FC8K- HALFINCH
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 457
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete Sample from Wheelbarrow
Where the material sample would have been placed if not sampled: G-11.017
From Lot No.:
Bag Lot No.:
DIME Test ID: 2026-07-27-27-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/24/2026
Date Tested: 08/24/2026
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Apparent mass of submerged cylinder 1
|
5.38 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
8700 psi
|
|
Maximum load on cylinder 1
|
110700 lb
|
|
Maximum load on cylinder 2
|
110030 lb
|
|
Maximum load on cylinder 3
|
107360 lb
|
|
Compressive strength of cylinder 1
|
8810.0 psi
|
|
Type of fracture pattern of cylinder 1
|
1
|
|
Compressive strength of cylinder 2
|
8750.0 psi
|
|
Compressive strength of cylinder 3
|
8540 psi
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Type of fracture pattern of cylinder 3
|
1
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|