Print Report | Back to Sample Detail

Sample Record for 2026-07-14-86

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1002415 DEA: 113A9414 EFIS: 1125000155 QA Service Level: 1
DIST-CO-RTE-PM: 11---unknown
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-07-14-86
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/14/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/15/2026
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: Plant Sample
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: MM Lakeside

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 23418180AH
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%): 0
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2026-07-14-86-1
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 08/12/2026
Date Tested: 07/31/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Diameter =2.5", complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of Cores 1
Core ID A1
Dry Weight 489.9 grams
Parrafin Coated Weight 502.9 grams
Coated Weight in Water 272.9 grams
Theoretical Maximum Density 2.459

Test

DIME Test ID: 2026-07-14-86-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/31/2026
Date Tested: 07/31/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target 7.5%, does not comply, oven 4
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3926.9 g
Mass of the specimen and specimen basket assembly prior to ignition 5977.1 g
Mass of HMA Sample prior to ignition 2050.2 g
Corrected Asphalt Binder Content 6.61 %
Mass Loss 150.6 g
Mass of aggregate remaining after ignition 1899.6 g
Correction Factor (Percent by mass of HMA Specimen) 0.74 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test

DIME Test ID: 2026-07-14-86-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/31/2026
Date Tested: 07/31/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 2560.4 grams
Mass of container filled with the sample and water for Sample 1 8994.8 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.459
Theoretical maximum density at 25°C (77°F) 2451.9 kg/m^3

Test

DIME Test ID: 2026-07-14-86-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/07/2026
Date Tested: 08/07/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Retest does not comply. Tested 6.90%, min is 7.1%.
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4044 g
Mass of the specimen and specimen basket assembly prior to ignition 6078.7 g
Mass of HMA Sample prior to ignition 2034.7 g
Corrected Asphalt Binder Content 6.9 %
Mass Loss 155.4 g
Mass of aggregate remaining after ignition 1879.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.74 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C